Introduction 

Thank you for purchasing an Omega Model DFG207 digital force gauge; designed for push force and pull force testing in 
numerous applications across virtually every industry. 

With proper usage, we are confident that you will get many years of great service with this product. Omega instruments are 
ruggedly built for many years of service in laboratory and industrial environments. 

This User’s Guide provides setup, safety, and operation instructions. Dimensions and specifications are also provided. For 

additional information or answers to your questions, please do not hesitate to contact us. Our technical support and 
engineering teams are eager to assist you. 

Before use, each person who is to use a Model DFG207 should be fully trained in appropriate operation and safety 
procedures. 

1.1

 

Safety/Proper Usage 

Caution: 

Please read this manual carefully before measurement, keep it properly after reading, in 

preparation to read again. 

It is possible to damage the gauge or cause serious accident if the device is operated incorrectly. Proper usage
of the device is described in the manual.

If the device is being used to test impact load, select a model with a safe load range of at least double the
impact load.

In destructive testing, protective masks and gloves should be worn to prevent the occurrence of the damage
to the human body because of material splashing during testing.

Do not use fixtures which have been damaged or severely bent. For users, please refer to the relevant
specifications in this manual when using a self-made fixture (various types of fixtures are provided for
customers to select according to need).

Do not test force exceeding the maximum range of the gauge. Otherwise, it may cause damage to the sensor,
or even an accident.

When the tested force exceeds 110% of the range, a continuous buzzer alarm will activate. In this case, please
remove the load quickly, or reduce the load.

When using the power adapter, the voltage of power supply should be the same as the rated voltage, or it
may cause electric shock or fire

Do not pull out or insert the plug with wet hands, or it may lead to electric shock.

Don't pull the cable of the power adapter to pull the plug, to avoid wire broken and electric shocks.

Please use a soft cloth to clean the gauge. Soak the cloth in the water with cleaning agent, wring it out, and
then use it to remove the dust and dirt.

Note: 

Do not use volatile chemicals to clean the gauge (such as volatile agents, thinner, alcohol, etc.).

 

Summary of Contents for DFG207

Page 1: ...1 M 5 7 9 3 TM User sGuide Shop online at omega com e mail info omega com For latest product manuals www omega com en us pdf manuals DFG207 Digital Force Gauge...

Page 2: ...6 USA Canada only U S A Headquarters Tel 203 359 1660 e mail info omega com Fax 203 359 7700 The information contained in this document is believed to be correct but OMEGA accepts no liability for any...

Page 3: ...creen Controls 7 4 1 Overall Structure 7 4 2 Display 8 4 3 Operation Key 9 5 Operating Modes 10 5 1 Real Time Measurement Mode Peak Hold Mode 10 5 2 Unit Conversion Function 10 5 3 Setting of Auto Pow...

Page 4: ...impact load select a model with a safe load range of at least double the impact load In destructive testing protective masks and gloves should be worn to prevent the occurrence of the damage to the h...

Page 5: ...y POWER EXIT for about 2 seconds the indicator OFF appears Then release the key and the gauge will be powered off Auto Power Off The Auto power off function can be activated by the user When it is act...

Page 6: ...the force gauge to use self made fixtures please refer to the relevant data on the next page Step 2 When measuring hold the force gauge firmly or install it on a suitable test machine Apply the force...

Page 7: ...gauge It can be connected to accessories such as the pull hook the flat measurement head the conical measurement head the V shape groove measurement head the V shape wedge measurement head the length...

Page 8: ...e pushing force is a positive value not shown the pulling force is a negative value display 4 12 Peak Value Indicator MAX When the indicator MAX appears it indicates that the device is in Peak Value H...

Page 9: ...going into the Auto Power Off Settings 4 20 Read Downward Key READ The key for entering Data Scanning Mode for transferring data from the gauge to the computer for downward scanning in Data Scanning M...

Page 10: ...quirements Then press the Zero Key ZERO to calibrate the gauge a value of zero will appear on the display When the weight of the used fixture is more than 20 of the range or the load of the gauge is m...

Page 11: ...d 150 FS Buzzer Alarm Over 110 FS Data Output USB Power Supply 2x AA Battery or 6V DC Power Supply Operating Conditions Temperature 0 40 C 0 104 F Humidity 80 Surrounding No Vibration Source or Corros...

Page 12: ...12 M 5 7 9 3 8 2 Specification and Application of Accessories...

Reviews: