background image

1 | 

M 5 7 9 3

TM

 

User’s Guide

 

Shop online 

at 

omega.com

 

e-mail: [email protected]

For latest product 

manuals: 

www.omega.com/en-

us/pdf-manuals 

DFG207

 

Digital Force Gauge  

Summary of Contents for DFG207

Page 1: ...1 M 5 7 9 3 TM User sGuide Shop online at omega com e mail info omega com For latest product manuals www omega com en us pdf manuals DFG207 Digital Force Gauge...

Page 2: ...6 USA Canada only U S A Headquarters Tel 203 359 1660 e mail info omega com Fax 203 359 7700 The information contained in this document is believed to be correct but OMEGA accepts no liability for any...

Page 3: ...creen Controls 7 4 1 Overall Structure 7 4 2 Display 8 4 3 Operation Key 9 5 Operating Modes 10 5 1 Real Time Measurement Mode Peak Hold Mode 10 5 2 Unit Conversion Function 10 5 3 Setting of Auto Pow...

Page 4: ...impact load select a model with a safe load range of at least double the impact load In destructive testing protective masks and gloves should be worn to prevent the occurrence of the damage to the h...

Page 5: ...y POWER EXIT for about 2 seconds the indicator OFF appears Then release the key and the gauge will be powered off Auto Power Off The Auto power off function can be activated by the user When it is act...

Page 6: ...the force gauge to use self made fixtures please refer to the relevant data on the next page Step 2 When measuring hold the force gauge firmly or install it on a suitable test machine Apply the force...

Page 7: ...gauge It can be connected to accessories such as the pull hook the flat measurement head the conical measurement head the V shape groove measurement head the V shape wedge measurement head the length...

Page 8: ...e pushing force is a positive value not shown the pulling force is a negative value display 4 12 Peak Value Indicator MAX When the indicator MAX appears it indicates that the device is in Peak Value H...

Page 9: ...going into the Auto Power Off Settings 4 20 Read Downward Key READ The key for entering Data Scanning Mode for transferring data from the gauge to the computer for downward scanning in Data Scanning M...

Page 10: ...quirements Then press the Zero Key ZERO to calibrate the gauge a value of zero will appear on the display When the weight of the used fixture is more than 20 of the range or the load of the gauge is m...

Page 11: ...d 150 FS Buzzer Alarm Over 110 FS Data Output USB Power Supply 2x AA Battery or 6V DC Power Supply Operating Conditions Temperature 0 40 C 0 104 F Humidity 80 Surrounding No Vibration Source or Corros...

Page 12: ...12 M 5 7 9 3 8 2 Specification and Application of Accessories...