background image

10

11

This window can be used to select the direction of rota-

tion (clockwise, “CW”, anti-clockwise “CCW”, or both) 

as well as the number of rotations. If only one direction is 

selected, the corresponding box for the opposite direc-

tion will be greyed out. Otherwise, both settings can be 

edited. The number of clockwise turns and the number 

of anti-clockwise turns are entirely independent of each 

other. For example, the rotating winder can be set to 

500 clockwise turns and 200 anti-clockwise turns. The 

maximum number of turns in either direction is 65,535. 

The final setting “Wait Time” is used to define the length 

of time between the two cycles. This is measured from 

the end of one set of revolutions to the start of the next. 

If the turn cycle lasts 1 hour and the wait time is 23 hours, 

the complete cycle will be repeated once every 24 hours. 

The maximum wait time is 1,092 hours and 15 minutes. 

When the desired settings have been configured, press 

the “Update” button to transfer them to the rotating 

winder. Once the transfer is complete, click on “Save 

and Disconnect”. The settings will not be saved by the 

rotating winder until this has been done. This action will 

deactivate Bluetooth mode and return the winder to nor-

mal mode. The rotating winder will start operating with 

an initial series of 12 clockwise rotations and 12 anti-clo-

ckwise rotations. Then it will follow the new settings for 

the wait time and the number of rotations. If the ON/OFF 

button is pressed before the interface is disconnected, 

the new settings will not be saved.

3.2  CONFIGURING STANDARD SETTINGS

Once the application is launched, click the “Open” 

button. The interface will automatically retrieve the 

settings saved in the rotating winder and display them in 

the appropriate fields. If these fields remain empty, press 

the “Refresh” button. If an error message appears, check 

that the winder is still in Bluetooth mode (LED flashing 

every two seconds). If the winder has reverted to nor-

mal mode (because the connection was not established 

within one minute), switch it off with a short press of the 

button. The Bluetooth mode can then be reactivated by 

holding the button down for four seconds.

MAC APPLICATION

WINDOWS APPLICATION

Summary of Contents for Cylinder

Page 1: ...INDER ON OFF 3 2 2 PUTTING AWATCH INTO THE OMEGA CYLINDER OR REMOVING IT 5 2 3 TORQUELIMITER protectionagainstjamming 6 2 4 CHANGING THE BATTERIES 6 2 5 BATTERYPOLARITY 8 3 BLUETOOTH CONFIGURATION 3 1...

Page 2: ...ed Do not press the button for more than four seconds as this will activate the Bluetooth configuration mode see chapter 3 The device s LED flashes to indicate the status of the batteries 4 flashes ba...

Page 3: ...e it will stop upside down When the batteries are nearly flat the LED may no longer light up The motor will continue to turn but can be expected to do so more slowly The batteries should be replaced t...

Page 4: ...n setting can be adjusted using the configuration tool s advanced mode refer to chapter 3 3 2 3 TORQUE LIMITER protection against jamming The OMEGA Cylinder has a motor current controller that protect...

Page 5: ...o launch the detection of the rotating winder This will only succeed if the winder is properly connected to the computer Once the appli cation has been located and connected the winder will remain in...

Page 6: ...inder Once the transfer is complete click on Save and Disconnect The settings will not be saved by the rotating winder until this has been done This action will deactivate Bluetooth mode and return th...

Page 7: ...g it can indicate if the motor is damaged Detection Threshold This final setting is used to alter the level at which the watch is detected in the rotating winder If the sensor does not detect the watc...

Page 8: ...Then press Update and disconnect the winder 4 SPECIFICATIONS Power supply FourAALR6 lithium alkaline 1 5Vbatteries Batterylife Around 2 years at 700 turns per day Rotation speed 10 turns per minute C...