background image

6

7

a   Remove the watch holder (1) 

by unclipping it and pulling it 

straight from the device.

b   Using the special tool provided 

(2), unscrew the central screw (3) 

as shown.

c   Remove the cover (4).
d   Insert 4 AA lithium/alkaline 1.5V 

(LR6) batteries into the housings 

(5), ensuring that they are the 

right way round. (Check the  

markings on the battery housings.) 

e   Replace the lid carefully. 
f    Tighten the central screw using 

the special tool.

g   Ensure that the cover turns freely.
h   Press the button on the front 

to ensure that the device 

is charged and start the cycle. 

   (N.B. The cycle will only begin 

if there is a watch in the watch 

holder.)

Press the button to turn the winder on. The pre-programmed 

cycle will begin immediately.

If the device does not detect the watch correctly (it does 

not move despite the fact that there is a watch on the 

holder) the detection setting can be adjusted using 

the configuration tool’s advanced mode (refer to 

chapter 3.3).

2.3  TORQUE LIMITER (protection against jamming)

The OMEGA Cylinder has a motor current controller that 

protects against jamming. If the motor current exceeds a 

predefined value (see chapter 3.3), it will turn off com-

pletely to protect the mechanism and avoid draining 

the batteries.

The current is measured every two seconds, meaning 

that the device can take up to two seconds to detect a 

jam. It will not start up again until the user presses the 

button, after having ensured that nothing is stopping 

the mechanism from moving freely.

2.4  CHANGING THE BATTERIES

The batteries need to be replaced when they are no lon-

ger capable of turning the OMEGA Cylinder (once every 

two years with average use). To avoid reaching the point 

where the batteries are no longer able to turn the device 

on, they should be replaced once there is less than 

30% charge remaining (one single flash on start-up). 

To replace the batteries, proceed as follows :

1

2

3

4

5

5

5

5

Summary of Contents for Cylinder

Page 1: ...INDER ON OFF 3 2 2 PUTTING AWATCH INTO THE OMEGA CYLINDER OR REMOVING IT 5 2 3 TORQUELIMITER protectionagainstjamming 6 2 4 CHANGING THE BATTERIES 6 2 5 BATTERYPOLARITY 8 3 BLUETOOTH CONFIGURATION 3 1...

Page 2: ...ed Do not press the button for more than four seconds as this will activate the Bluetooth configuration mode see chapter 3 The device s LED flashes to indicate the status of the batteries 4 flashes ba...

Page 3: ...e it will stop upside down When the batteries are nearly flat the LED may no longer light up The motor will continue to turn but can be expected to do so more slowly The batteries should be replaced t...

Page 4: ...n setting can be adjusted using the configuration tool s advanced mode refer to chapter 3 3 2 3 TORQUE LIMITER protection against jamming The OMEGA Cylinder has a motor current controller that protect...

Page 5: ...o launch the detection of the rotating winder This will only succeed if the winder is properly connected to the computer Once the appli cation has been located and connected the winder will remain in...

Page 6: ...inder Once the transfer is complete click on Save and Disconnect The settings will not be saved by the rotating winder until this has been done This action will deactivate Bluetooth mode and return th...

Page 7: ...g it can indicate if the motor is damaged Detection Threshold This final setting is used to alter the level at which the watch is detected in the rotating winder If the sensor does not detect the watc...

Page 8: ...Then press Update and disconnect the winder 4 SPECIFICATIONS Power supply FourAALR6 lithium alkaline 1 5Vbatteries Batterylife Around 2 years at 700 turns per day Rotation speed 10 turns per minute C...