OMEGA’s  policy  is  to  make  running  changes,  not  model  changes,  whenever  an  improvement  is  possible.  This  affords  our 

customers the latest in technology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC.
©  Copyright  2017  OMEGA  ENGINEERING,  INC.  All  rights  reserved.  This  document  may  not  be  copied,  photocopied, 

reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior 

written consent of OMEGA ENGINEERING, INC.

FOR 

WARRANTY

 RETURNS, please have the  

following information available BEFORE contacting 

OMEGA:
1.   Purchase Order number under which the product 

was PURCHASED,

2.   Model and serial number of the product under 

warranty, and

3.  Repair instructions and/or specific problems  

  relative to the product.

FOR 

NON-WARRANTY

 REPAIRS, consult 

OMEGA for current repair charges. Have 

the following information available BEFORE 

contacting OMEGA:
1.  Purchase Order number to cover the COST  

  of the repair,
2.  Model and serial number of the product, and
3.  Repair instructions and/or specific problems  

  relative to the product.

RETURN REQUESTS/INQUIRIES

Direct  all  warranty  and  repair  requests/inquiries  to  the  OMEGA  Customer  Service  Department.  BEFORE 

RETURNING  ANY  PRODUCT(S)  TO  OMEGA,  PURCHASER  MUST  OBTAIN  AN  AUTHORIZED  RETURN  (AR) 

NUMBER  FROM  OMEGA’S  CUSTOMER  SERVICE  DEPARTMENT  (IN  ORDER  TO  AVOID  PROCESSING 

DELAYS). The assigned AR number should then be marked on the outside of the return package and on any 

correspondence.
The  purchaser  is  responsible  for  shipping  charges,  freight,  insurance  and  proper  packaging  to  prevent 

breakage in transit.

WARRANTY/DISCLAIMER

OMEGA  ENGINEERING,  INC.  warrants  this  unit  to  be  free  of  defects  in  materials  and  workmanship  for  a 

period of 

13 months

 from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace 

period to the normal 

one (1) year product warranty

 to cover handling and shipping time. This ensures 

that OMEGA’s customers receive maximum coverage on each product.
If  the  unit  malfunctions,  it  must  be  returned  to  the  factory  for  evaluation.  OMEGA’s  Customer  Service 

Department  will  issue  an  Authorized  Return  (AR)  number  immediately  upon  phone  or  written  request. 

Upon  examination  by  OMEGA,  if  the  unit  is  found  to  be  defective,  it  will  be  repaired  or  replaced  at  no 

charge.  OMEGA’s  WARRANTY  does  not  apply  to  defects  resulting  from  any  action  of  the  purchaser, 

including  but  not  limited  to  mishandling,  improper  interfacing,  operation  outside  of  design  limits,  

improper  repair,  or  unauthorized  modification.  This  WARRANTY  is  VOID  if  the  unit  shows  evidence  of  

having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; 

or  current,  heat,  moisture  or  vibration;  improper  specification;  misapplication;  misuse  or  other  operating 

conditions  outside  of  OMEGA’s  control.  Components  in  which  wear  is  not  warranted,  include  but  are  not  

limited to contact points, fuses, and triacs.

OMEGA  is  pleased  to  offer  suggestions  on  the  use  of  its  various  products.  However,  

OMEGA  neither  assumes  responsibility  for  any  omissions  or  errors  nor  assumes  liability  for 

any damages that result from the use of its products in accordance with information provided 

by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the 

company will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR  

REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF 

TITLE,  AND  ALL  IMPLIED  WARRANTIES  INCLUDING  ANY  WARRANTY  OF  MERCHANTABILITY 

AND  FITNESS  FOR  A  PARTICULAR  PURPOSE  ARE  HEREBY  DISCLAIMED.  LIMITATION  OF  

LIABILITY:  The  remedies  of  purchaser  set  forth  herein  are  exclusive,  and  the  total  liability  of  

OMEGA  with  respect  to  this  order,  whether  based  on  contract,  warranty,  negligence,  

indemnification,  strict  liability  or  otherwise,  shall  not  exceed  the  purchase  price  of  the  

component  upon  which  liability  is  based.  In  no  event  shall  OMEGA  be  liable  for  

consequential, incidental or special damages.

CONDITIONS:  Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic 

Component”  under 10 CFR  21 (NRC), used in or  with any  nuclear  installation  or  activity;  or  (2)  in  medical 

applications  or  used  on  humans.  Should  any  Product(s)  be  used  in  or  with  any  nuclear  installation  or 

activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility 

as  set  forth  in  our  basic  WARRANTY/DISCLAIMER  language,  and,  additionally,  purchaser  will  indemnify 

OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the 

Product(s) in such a manner.

Summary of Contents for CL110

Page 1: ...NORWALK CT e mail info omega com For latest product manuals www omegamanual info Shop online at omega com SM User sGuide CL110 Precision Loop Calibrator ...

Page 2: ...specifications without notice omega com info omega com Servicing North America U S A Omega Engineering Inc Headquarters Toll Free 1 800 826 6342 USA Canada only Customer Service 1 800 622 2378 USA Canada only Engineering Service 1 800 872 9436 USA Canada only Tel 203 359 1660 Fax 203 359 7700 e mail info omega com For Other Locations Visit omega com worldwide ...

Page 3: ...atures Large easy to read display for measurements and data entry Digital knob with selectable decade control for quick and easy data entry Interactive menus Input and output jacks protected by self resetting fuses providing protection to 240VAC 1 1 Customer Service OMEGA Engineering Tel 203 359 1660 Fax 203 359 7900 www omega com email info omega com 1 2 Standard Equipment Check to see if your ca...

Page 4: ...these symbols may be used on the instrument or in this manual Symbol Description AC Alternating Current AC DC Battery CE Complies with European Union Directives DC Double Insulated Electric Shock Fuse PE Ground Hot Surface Burn Hazard Read the User s Manual Important Information Off On Canadian Standards Association ...

Page 5: ...articular attention to the insulation surrounding the connectors Select the proper function and range for your measurement Make sure the battery cover is closed and latched before you operate the calibrator Remove test leads from the calibrator before you open the battery door Inspect the test leads for damaged insulation or exposed metal Check test leads continuity Replace damaged test leads befo...

Page 6: ...y as soon as the battery indicator appears To avoid a violent release of pressure in a pressurized system shut off the valve and slowly bleed off the pressure before you attach the pressure module to the pressure line Caution To avoid possible damage to calibrator or to equipment under test Use the proper jacks function and range for your measurement or sourcing application ...

Page 7: ...n display for all operating modes It shows the present measurement or output value The individual operating modes are described below Use the MENU EXIT key to display the main menu described in section 3 to select the primary operating mode of the calibrator or to access the calibrator setup functions In output mode Press the knob to move the decade cursor Rotate the knob to increment or decrement...

Page 8: ...4 000mA 4 20mA INPUT DEVICE RECORDER INDICATOR SCADA SYSTEM ETC 4 to 20mA Figure 2 Press the knob to move the decade cursor Rotate the knob to increment or decrement the output in steps indicated by the selected decade Use the 3 percent keys to directly set the output to preset values Use the step ramp key to select and stop these advanced modes which are described in section 5 1 When automatic st...

Page 9: ... from an external power supply This function is a great way to test a loop with the transmitter removed Figure 3 shows the main display and typical connections for this mode Precision Loop Calibrator 100 25 0 MENU EXIT Simulate 0 00 4 000mA POWER SUPPLY 30 VDC MAX 4 to 20mA 4 20mA INPUT DEVICE Figure 3 Press the knob to move the decade cursor Rotate the knob to increment or decrement the output in...

Page 10: ...n the HART resistor has been enabled on the Setup Menu section 4 4 2 3 Milliamp Measure without 24V power In the mA Measure mode the calibrator displays the loop current Figure 4 shows the main display and typical connections for this mode Precision Loop Calibrator 100 25 0 MENU EXIT Measure 0 00 4 000mA 4 20mA OUTPUT DEVICE 4 to 20mA Figure 4 Press MENU EXIT to enter the main menu described in se...

Page 11: ...s mode Precision Loop Calibrator 100 25 0 MENU EXIT Measure 24V 0 00 4 000mA Figure 5 Press MENU EXIT to enter the main menu described in section 3 The text 250Ω text is shown in the lower right corner when the HART resistor has been enabled on the Setup Menu section 4 4 2 5 Volts Measure In the Volts Measure mode the calibrator displays the loop voltage Figure 6 shows the main display and typical...

Page 12: ...e mA Measure mA Measure with 24V Volts Measure Calibrator Setup Menu Rotate the knob to select an action by moving the reverse video highlight up and down Press the knob to perform the selected action Press MENU EXIT to return to the main display without performing an action The first five actions change the operating mode accordingly and return to the main display described in section 2 The Calib...

Page 13: ...everse video highlight up and down Press the knob to perform the selected action Press MENU EXIT to return to the main display without performing an action 4 1 Setting Auto Ramp Time Auto Ramp Time 10 SEC Press hold to Save This function sets the full scale ramp time for the mA ramp feature described in more detail in section 5 1 The value can be set from 5 to 300 seconds Rotate the knob to adjust...

Page 14: ...ress and hold the knob to save it Press MENU EXIT to restore the previous value and return to the main display 4 3 Enabling Valve Test Valve Test Enable OFF ON This function enables and disables the valve test feature described in more detail in section 5 2 Rotate the knob to move the reverse video highlight to the desired selection Press the knob to save the highlighted selection Press MENU EXIT ...

Page 15: ...lects the mA span used to calculate the percent of span field on the main display and to set the value used by the 0 key Rotate the knob to move the reverse video highlight to the desired selection Press the knob to save the highlighted selection Press MENU EXIT to restore the previous selection and return to the main display 4 6 Contrast Adjustment Contrast Sample normal video Sample reverse vide...

Page 16: ...p Menus How the features are enabled and what they do is described below 5 1 Step and Ramp Operation The calibrator has several unique features that are helpful aids when doing milliamp calibrations The percent keys allow the user to set the milliamp output to 0 of span 100 of span or step it by 25 of span The Step Ramp key allows hands free operation by automatically stepping or ramping the milli...

Page 17: ...specified interval Press one of the percent keys or the Step Ramp once more to turn off the auto step and ramp 5 2 Valve Test The calibrator has a valve test mode for verifying proper operation of valves In valve test the user can step the output to the following values 3 8 mA 4 0mA 4 2mA 8 0 mA 12 0 mA 16 0 mA 19 8 mA 20 0 mA 20 2 mA and back The valve test mA values are not affected by the mA sp...

Page 18: ...d personal injury or damage to the calibrator use only the specified replacement parts and do not allow water into the case Caution To avoid damaging the plastic lens and case do not use solvents or abrasive cleaners Clean the calibrator with a soft cloth dampened with water or water and mild soap 6 3 Fuse Protection The CL110 is protected with an internal polyfuse against overcurrent conditions T...

Page 19: ...55 C Display 128 x 64 pixels LCD Graphic w backlight 34 high digits Power 6AAA alkaline lithium or NiMH batteries Battery Life 40 hours continuous use measure mode Loop Compliance Voltage 24VDC 20mA Loop Drive Capability 1200Ω without HART resistor 950 Ω with HART resistor Over Voltage Protection 240VAC Overload Current Protection 28mA DC EMC EN61326 Annex A Portable Instruments Dimensions LxWxD 6...

Page 20: ... by OMEGA if the unit is found to be defective it will be repaired or replaced at no charge OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser including but not limited to mishandling improper interfacing operation outside of design limits improper repair or unauthorized modification This WARRANTY is VOID if the unit shows evidence of having been tampered with or...

Page 21: ...s Air Velocity Indicators Turbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pumps Industrial pH Conductivity Equipment DATA ACQUISITION Communications Based Acquisition Systems Data Logging Systems Wireless Sensors Transmitters Receivers Signal Conditioners Data Acquisition Softwa...

Reviews: