background image

SERIAL PORT

3F8-3FF

EGA

2B0-2BF

FLOPPY DISK

3F0-3F7

PARALLEL PRINTER

270-27F

SERIAL PORT

3E8-3EF

ALT BUS MOUSE

23C-23F

CGA

3D0-3DF

BUS MOUSE

238-23B

EGA

3C0-3CF

EXPANSION UNIT (XT)

210-21F

FUNCTION

HEX

RANGE 

FUNCTION

HEX

RANGE

The CIO-CTR BASE switch may be set for address in the range of 000-3F8 (000-3FC
for the CIO-CTR05) so it should not be hard to find a free address area for your CIO-
CTR.  Once again, if you are not using IBM prototyping cards or some other board
which occupies these addresses, then 300-31F HEX are free to use.

Address not specifically listed, such as 390-39F, are usually free.

INTERRUPT LEVEL SELECT

There are two rows of jumper blocks on the CIO-CTR10 and one on the CIO-CTR05,
located just above the PC bus interface (gold pins).  The factory default setting is that
no interrupt level is set.  The jumper is in the 'X' position.

Please leave the jumper in the 'X' position for now.  Interrupts are hardware initiated
software routines and are discussed in the section on programming.

On the CIO-CTR10 the lower block,
J2, is for the IR input on P1.  The
upper block, J3, is for the IR input
on P2

The trigger logic on the CIO-CTR is
quite simple.  Pin 1 of the 37 pin
connector is an input jumper which
maps the interrupt directly onto the
PC bus.  The signal to the bus is
buffered. The buffer is enabled by a
TTL low level on Pin 2, interrupt
enable.

The interrupt level jumper on the
CIO-CTR must also be installed.
Move it from the 'X' position to the
IRQ number you want the interrupt pulse on.  On the CTR10, jumper block J2 is asso-
ciated with the signals on connector P1.  Jumper block J3 is associated with the sig-
nals on connector P2.

5

2

3

4

5 6

7 X

J3

Input at P2

J2

Input at P1

CIO-CTR INTERRUPT JUMPER BLOCK - IRQ
Level.  The jumper is in the X position 
which equals no IRQ.

ENVIRONMENTAL

5 Oz.

Weight

0 to 90% Non-Condensing

Humidity

-20 to 70 Deg C

Storage Temperature

0-50 Deg C

Operating Temperature

14

Summary of Contents for CIO-CTR05

Page 1: ...User s Guide http www omega com e mail info omega com CIO CTR05 CIO CTR10...

Page 2: ...ER CONSUMPTION 13 SPECIFICATIONS 12 DIGITAL I O REGISTERS 10 CIO CTR10 CIO CTR05 ADDRESSES 10 CONTROL DATA REGISTERS 10 CIO CTR ARCHITECTURE 9 SOFTWARE 8 CIO CTR10 SECOND 9513 7 INSTALLING THE CIO CTR...

Page 3: ...iskette some releases of InstaCal will provide SETUP EXE rather than Install EXE Use SETUP EXE if it is included on your InstaCal disk It will create all required folders directories and unpack the va...

Page 4: ...ub menus plus exit 1 Select Install either highlight it and hit enter or double click your mouse on it 2 Select Board 0 select another number if Board 0 is already installed 3 Select Board Type 4 Move...

Page 5: ...og input Attenuation R1 R2 R2 Digital inputs also make use of voltage dividers for example if you wish to measure a digital signal that is at 0 volts when off and 24 volts when on you cannot connect t...

Page 6: ...have access to the InstaCAL program The CIO CTR has one bank of switches a base address switch and one jumper block which must be set before installing the board in your computer The calibration and...

Page 7: ...ave the jumper in the X position for now Interrupts are hardware initiated software routines and are discussed in the section on programming On the CIO CTR10 the lower block J2 is for the IR input on...

Page 8: ...FLOPPY DISK IRQ6 HARD DISK IRQ14 HARD DISK AT LPT AT IRQ5 80287 NUMERIC CO P IRQ13 COM OR SDLC IRQ4 UNASSIGNED IRQ12 COM OR SDLC IRQ3 UNASSIGNED IRQ11 RESERVED XT INT 8 15 AT IRQ2 UNASSIGNED IRQ10 KE...

Page 9: ...IO CTR The CIO CTR connector is a male 37 pin D type connector All the signals from the 9513 digital input digital output and interrupt are accessible The CTR10 has two of these connectors P1 and P2 T...

Page 10: ...gital output port P2 No read back of output port BASE 7 Digital input port P2 BASE 6 Cammands to 9513 2 Status of 9513 2 BASE 5 Data for 9513 2 Data from 9513 2 BASE 4 CTR 10 ONLY Digital output port...

Page 11: ...each counter the 9513 is fully programmable and any counter may be internally con nected to any gate and receive it s counts from a number of sources In addition each counter does not have a unique I...

Reviews: