53
Appendix B: Scaling the Load Cell Input
The full scale of the input coming from the load cell may be adjusted by
the LK4 jumper (which is next to load cell connector):
•
Across the two
leftmost
pins (default):
Load cell output is 1-2mV/V.
•
Across the two
rightmost
pins:
Load cell output is 3mV/V.