background image

 

USA:   

 

One Omega Drive, P.O. Box 4047 

ISO 9001 Certified 

Stamford CT 06907-0047 

 

 

 

TEL: (203) 359-1660   

FAX: (203) 359-7700 

 

 

 

e-mail: 

[email protected]

 

 

Canada: 

 

976 Bergar 

 

 

 

Laval (Quebec) H7L5A1 

 

 

 

TEL: (514) 856-6928   

FAX: (514) 856-6886 

 

 

 

e-mail: 

[email protected]

 

 

For immediate technical or application assistance: 

 

USA and Canada: 

Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA 

 

 

 

Customer Service:  1-800-622-2378 / 1-800-622 BEST 

 

 

 

Engineering Service:  1-800-872-9436 / 1-800-USA-WHEN 

 

 

 

TELEX: 996404    EASYLINK: 62968934   CABLE: OMEGA 

 

Mexico: 

 

En Español: (001) 203-359-7803   e-mail:[email protected] 

 

 

 

 

 

 

 

 

             

[email protected]

 

 

Servicing Europe: 

 

Benelux: 

 

Postbus 8034, 1180 LA Amstelveen, The Netherlands 

 

 

 

TEL: +31 (0)20 3472121 

 

FAX: +31 (0)20 6434643 

 

 

 

Toll Free in Benelux:  0800 0993344 

 

 

 

e-mail: 

[email protected]

 

 

Czech Republic: 

Rudé armády 1868,733 01 Karviná 8 

 

 

 

TEL: +420 (0)69 6311899 

 

FAX:   +420 (0)69 6311114 

 

 

 

Toll Free: 0800-1-66342 

 

France: 

 

9, rue Denis Papin, 78190 Trappes 

 

 

 

TEL: +33 (0)130 621 400 

 

 FAX:  +33 (0)130 699 120 

 

 

 

Toll Free in France: 0800-4-06342 

 

 

 

e-mail:[email protected]  

 

Germany/  

 

Daimlerstrasse 26, D-75392  Deckenpfronn, Germany 

Austria: 

 

TEL: +49 (0)7056 9398-0 

 

FAX:  +49 (0)7056 9398-29 

 

 

 

Toll Free in Germany: 0800 639 7678 

 

 

 

e-mail:[email protected] 

 

United Kingdom: 

One Omega Drive, River Bend Technology Centre 

ISO 9002 Certified 

Northbank, Irlam, Manchester 

 

 

 

M44 5ex United Kingdom 

 

 

 

TEL: +44 (0)161 777 6611 

 

 

FAX: +44 (0)161 777 6622 

 

 

 

Toll Free in United Kingdom:0800-488-488 

 

 

 

e-mail:[email protected]

 

 

 

It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply.  
OMEGA is constantly pursuing certification of its products to the European New Approach Directives.  
OMEGA will add the CE mark to every appropriate device upon certification. 

 

The information contained in this document is believed to be correct, but OMEGA Engineering, Inc. 
accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. 

WARNING:  

These products are not designed for use in, and should not be used for, patient-connected 

applications. 
 

Where Do I Find Everything I Need for 

Summary of Contents for DP97

Page 1: ......

Page 2: ...ions v wire recognition 4 INSTRUMENT RE CALIBRATION 6 5 ANALOGUE RE TRANSMISSION OUTPUT 8 Connection and Operation 6 RS232 COMMUNICATIONS 9 Connection and Operation Using RS232 interface for digital p...

Page 3: ...t 3 or 4 wire mode Display of input A B OR a B differential can be selected a differential zero function allows sensor accuracy differences to be eliminated for accurate differential readings An RS232...

Page 4: ...channel selected cycle between a steady on state and a brief off state occulting when corrections are stored and applied to measurements not applicable to version 1 4 To read differential temperatures...

Page 5: ...the appropriate rear panel mating connector Internal battery power can provide operation for up to 12 hours from full charge Low battery charge state is indicated by bAtt on the display Input Connect...

Page 6: ...r open circuit the LED display will show Err 3 Press any button to resume normal operation either select another channel or rectify any fault and continue intended use b Press CHANNEL to select inputs...

Page 7: ...Indications The DP97 has several modes of error indication according to internal or external problems as follows Display Cause Err 1 Calibration lost very unlikely Err 2 Software fault Err 3 Broken p...

Page 8: ...verify allow the DP97 to ead the currently selected channel and press SPAN s s once the display will now show 4 4 X 3 3 or 4 wire mode is allowable on either channel A or B i e A4 B3 or A3 B4 or A3 B3...

Page 9: ...are as follows At this point the existing calibration has now been over written by default values The procedure should therefore now be completed i Connect 100 Ohm calibration resistor to PRT INPUT a...

Page 10: ...1 V whenever the reading is at the span parameter as set by the user Any reading between zero and span will result in an Analogue output signal proportional to the position of the reading with respec...

Page 11: ...nd word length 9600 Baud 8 Data No parity 1 stop bit Remote control of calibration has not been included Refer to section 4 Protocol Command strings are limited to a single statement action will occur...

Page 12: ...th commas and spaces as delimiters All replies will be terminated by CR and LF The first number will be an error code 0 No error 1 Calibration lost EEPROM corruption 2 3 Broken probe 4 Syntax error 6...

Page 13: ...tions IC Initialise corrections i e Erase useful after installing software For these commands to be actioned theSPANs s key must be pressed as the command is typed Corrections entered as Follows Type...

Page 14: ...prompt select the drive if this is the correct drive for the PC in use i e C a ENTER At the a prompt type TM C and ENTER If using comms port 2 type TM C 2 After the introduction screen the MAIN MENU w...

Page 15: ...Page 13...

Page 16: ...Page 14...

Page 17: ...u Click SPECIFY Key file name into CURRENT SELECTION File names end with COR eg EXPI COR If COR is not keyed in it will be added automatically when ENTER is pressed or OK clicked Note File name should...

Page 18: ...ation lights occult at 8 second intervals It is important to note that the DP97 will revert to its standard resistance versus temperature values for Pt100 sensors and the channel annunciation light wi...

Page 19: ...ons Allow 5 to 10 minutes for full stability unless stored at low temperature then allow 30 minutes minimum Pt100 Sensor Current 0 5mA nominal Display Resolution 0 01 C K F Measurement Units C F K use...

Page 20: ...uracy Allow adequate warm up time if moved from region of low ambient temperature prior to use EMC Compliance Meets EMC regulations RFI to BS EN50081 1 1992 and immunity to BS EN 50082 1 1992 CE Compl...

Page 21: ...programming standard of custom calibration and preview of set values from a PC Also provides a print facility and storage of sets of correction values Analogue Output standard Analogue 0 to 1 Volt d...

Page 22: ...purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold by OMEGA is not intended to be...

Page 23: ...0 130 699 120 Toll Free in France 0800 4 06342 e mail france omega com Germany Daimlerstrasse 26 D 75392 Deckenpfronn Germany Austria TEL 49 0 7056 9398 0 FAX 49 0 7056 9398 29 Toll Free in Germany 08...

Page 24: ...bine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pumps Industrial pH Conductivity E...

Reviews: