WFIf - Installation and operating manual 

 

 

For bulk water vapour cyclonic separator must be installed. Flow direction outside-in must be provided 
as shown in the picture. General arrangement is filter head on top and filter bowl on bottom. 

 

 

 

 

 

 

 

 

 

 

 

Maintenance 

 

Filter elements are subject to wear. In order to maintain system efficiency, optimal performance and 
best air quality, these rules of proper maintenance should be followed: 

 

PI, PN25 and PN5 filter element can be cleaned with ultrasonic bath or with back flushing. 
Intervals of cleaning depend on application. If necessary replace filter element with new one. 

 

Replace PP, PR, PM, PS filter at least element every 12 months or when pressure drop reaches 
350 [mbar]. 

 

Replace PA filter element at least every 6 months. 

 

The housing O-ring can be damaged during filter element change. To prevent air leakage and 
malfunction replace housing O-ring if necessary. For replacement contact manufacturer. 

 

Damaged components are to be replaced by new ones. If a marked degree of damage is found, 
the entire filter is to be replaced.  

 

Filter has been designed for a life of 10 years in normal operating environment. After 10 years 
periodical checks of filter integrity are strongly recommended for safe operation. 

 

Carry out a check for leaks once the maintenance work has been finished. 

 

 

Cyclonic separator 

 

Output 

 

Input 

 

Summary of Contents for WFIf

Page 1: ...and operating manual WFIf Please read the following instructions carefully before installing filter housing unit into service Trouble free and safe operating of the unit can only be guaranteed if rec...

Page 2: ...WFIf Installation and operating manual 2 Components Part 1 Filter head 2 Sealing 3 Filter element 4 Filter bowl 5 Nut 3 2 1 4 5...

Page 3: ...6720 3 955 1288 410 456 219 1 1 43 64 WFIF 900 DN150 4X3030 10 9600 5 650 1310 480 273 0 1 77 87 WFIF 1200 DN150 6X3030 10 13440 7 910 1351 540 598 323 9 1 104 110 WFIF 1800 DN200 8X3030 10 17280 10...

Page 4: ...tegory 2 Module H WFIf 240 900 Category 3 Module H WFIf 1200 2000 Category 4 Module H1 PRESSURE EQUIPMENT DIRECTIVE PED 2014 68 EU Fluid group 2 WFIF 010 070 Article 4 3 WFIF 094 200 Category 1 Module...

Page 5: ...to ensure that the unit is equipped with the corresponding safety and test devices to prevent the permissible operating parameters from being exceeded Filter has been designed for a primarily static...

Page 6: ...are to be considered incorrect Specifically filter is not intended for human breathing without proper additional equipment Warning internal corrosion can seriously reduce the safety of installation c...

Page 7: ...WFIf Installation and operating manual 7 Installation For oil removal coalescing filter element must be installed Flow direction inside out must be provided 1 2 3 4 5 6 7 8 9 10 11 12...

Page 8: ...eplace filter element with new one Replace PP PR PM PS filter at least element every 12 months or when pressure drop reaches 350 mbar Replace PA filter element at least every 6 months The housing O ri...

Page 9: ...ng and maintenance The unit was not operated properly and appropriately The unit was operated when it was clearly defective Non original spare parts or replacement parts were used The unit was not ope...

Page 10: ...Installation and operating manual 10 OMEGA AIR d o o Ljubljana Cesta Dolomitskega odreda 10 SI 1000 Ljubljana Slovenia Tel 386 0 1 200 68 00 Fax 386 0 1 200 68 50 E mail info omega air si www omega ai...

Reviews: