background image

WFIf - Installation and operating manual 

 

 

Technical data 

FILTER 

HOUSING 

PIPE 

SIZE-D 

[inch] 

FILTER 

ELEMENT 

OPERATING 

PRESSURE 

FLOW CAPACITY 

 

DIMENSIONS [mm] 

VOLUME 

[l] 

WEIGHT 

[kg] 

[Nm

3

/h]  [scfm] 

B* 

WFIF 010 

DN15 

1X0420 

14 

150 

88 

230 

195  217 

76,1

 

1/2”

 

0,84 

3,5 

WFIF 018 

DN20 

1X0520 

14 

225 

132 

263 

201  219 

76,1

 

1/2”

 

0,93 

4,3 

WFIF 030 

DN25 

1X0525 

14 

315 

185 

279 

216  244 

88,9 

1/2”

 

1,4 

 

5,7 

WFIF 047 

DN32 

1X0725 

14 

420 

247 

343 

235  267 

88,9 

1/2”

 

1,74 

6,6 

WFIF 070 

DN40 

1X0730 

14 

600 

353 

391 

260  290  114,3 

1/2”

 

3,4 

8,0 

WFIF 094 

DN50 

1X1030 

14 

900 

530 

444 

270  304  114,3

 

1/2”

 

4,1 

9,8 

WFIF 150 

DN50 

1X1530 

14 

1260 

742 

571 

270  304  114,3

 

1/2”

 

5,3 

11,0 

WFIF 175 

DN65 

1X2030 

14 

1680 

989 

752 

295  340  139,7 

1/2”

 

10,2 

14,2 

WFIF 200 

DN80 

1X3030 

14 

2400 

1.413 

978 

306  340  139,7 

1/2”

 

14 

21,2 

WFIF 240 

DN80 

1X3050 

14 

3600 

2.119 

1041  332  368  168,3 

1/2”

 

21 

22,9 

WFIF 450  DN100  3X2030 

10 

5040 

2.966 

981 

410 

219,1 

1” 

36 

55 

WFIF 600  DN100  3X3030 

10

 

6720 

3.955 

1288  410  456  219,1 

1”

 

43 

64 

WFIF 900  DN150  4X3030 

10

 

9600 

5.650 

1310  480 

273,0 

1”

 

77 

87 

WFIF 1200  DN150  6X3030 

10

 

13440 

7.910 

1351  540  598  323,9 

1”

 

104 

110 

WFIF 1800  DN200  8X3030 

10

 

17280 

10.171  1496  660 

406,4 

1”

 

180 

200 

WFIF 2000  DN200  10X3030 

10

 

21120 

12.431  1496  660 

406,4 

1”

 

180 

200 

B = flange connection EN 1092-1/11 PN16 
B* = flange connection ANSI B16.5 WN Cl 150 
Flow capacity at 7 bar(g), 20°C 

 

MATERIALS 

 

 
 
 

 

CORRECTION FACTORS

 

To calculate the correct capacity of a given filter based on actual operating 
conditions, multiply the nominal flow capacity by the appropriate correction 
factor(s).  
CORRECTED CAPACITY = NOMINAL FLOW CAPACITY x C

OP 

 

[bar] 

10 

11 

12 

13 

14 

[psi] 

29 

44 

58 

72 

87 

100 

115 

130 

145 

160 

174 

189 

203 

C

OP 

0,38 

0,5 

0,63 

0,75 

0,88 

1,13 

1,25 

1,38 

1,50 

1,63 

1,75 

1,88 

 

* Actual operating temperature depends on sealing material and type of filter element. 

 

 

Housing material 

Stainless steel 

Sealing 

FKM 

Housing finishes 

Polished down to grade Ra1.6 

Lubricant 

(Optional Shell cassida grease RLS 2) 

Operating temperature 

-20 / + 150  °C * 

-4 / + 302 °F * 

Operating pressure

 

0 – 14 bar(g) 

0 – 203 psi 

A

B

ØC

E

E

Summary of Contents for WFIf

Page 1: ...and operating manual WFIf Please read the following instructions carefully before installing filter housing unit into service Trouble free and safe operating of the unit can only be guaranteed if rec...

Page 2: ...WFIf Installation and operating manual 2 Components Part 1 Filter head 2 Sealing 3 Filter element 4 Filter bowl 5 Nut 3 2 1 4 5...

Page 3: ...6720 3 955 1288 410 456 219 1 1 43 64 WFIF 900 DN150 4X3030 10 9600 5 650 1310 480 273 0 1 77 87 WFIF 1200 DN150 6X3030 10 13440 7 910 1351 540 598 323 9 1 104 110 WFIF 1800 DN200 8X3030 10 17280 10...

Page 4: ...tegory 2 Module H WFIf 240 900 Category 3 Module H WFIf 1200 2000 Category 4 Module H1 PRESSURE EQUIPMENT DIRECTIVE PED 2014 68 EU Fluid group 2 WFIF 010 070 Article 4 3 WFIF 094 200 Category 1 Module...

Page 5: ...to ensure that the unit is equipped with the corresponding safety and test devices to prevent the permissible operating parameters from being exceeded Filter has been designed for a primarily static...

Page 6: ...are to be considered incorrect Specifically filter is not intended for human breathing without proper additional equipment Warning internal corrosion can seriously reduce the safety of installation c...

Page 7: ...WFIf Installation and operating manual 7 Installation For oil removal coalescing filter element must be installed Flow direction inside out must be provided 1 2 3 4 5 6 7 8 9 10 11 12...

Page 8: ...eplace filter element with new one Replace PP PR PM PS filter at least element every 12 months or when pressure drop reaches 350 mbar Replace PA filter element at least every 6 months The housing O ri...

Page 9: ...ng and maintenance The unit was not operated properly and appropriately The unit was operated when it was clearly defective Non original spare parts or replacement parts were used The unit was not ope...

Page 10: ...Installation and operating manual 10 OMEGA AIR d o o Ljubljana Cesta Dolomitskega odreda 10 SI 1000 Ljubljana Slovenia Tel 386 0 1 200 68 00 Fax 386 0 1 200 68 50 E mail info omega air si www omega ai...

Reviews: