OMEGA AIR WFIf Installation And Operating Manual Download Page 5

WFIf - Installation and operating manual 

 

 

Safety instructions 

 

The relevant safety at work and accident prevention regulations, plus operating instructions, shall apply 
for operating the filter. The filter has been constructed in accordance with the generally recognized 
rules of engineering. It complies with the requirements of directive 2014/68/EU concerning pressure 
equipment. 

Ensure that installation complies with local laws for operation and routine testing of pressure 
equipment at the place of installation. 

Operator/user of the filter should make himself familiar with the function, installation and start-up of 
the unit. All the safety information is always intended to ensure your personal safety. 

 

Do not exceed max. operating pressure or operating temperature range (see data label). 

 

The permissible working temperatures and pressures for ad-on parts and filter elements 
are given under Technical data for those ad-ons. Maximum temperature and pressure for 
assembled system is the lowest of any individual part. 

 

It is necessary to ensure that the unit is equipped with the corresponding safety and test 
devices to prevent the permissible operating parameters from being exceeded. 

 

Filter has been designed for a primarily static pressure. Rapid changes of pressure are not 
allowed. 

 

The medium used may not have any corrosive components that could attack the 
materials of the filter in a way that is not permitted. Do not use the filter in hazardous 
areas with potentially explosive atmospheres. 

 

All installation and maintenance work on the filter may only be carried out by trained and 
experienced specialists. 

 

It is forbidden to carry out any kind of work on the filter and piping, including welding and 
constructional changes, etc. 

 

A pressure gauge, which shows the operational pressure, must be installed in the unit, 
respectively in the pipeline. 

 

Depressurize the system before carrying out the installation work. The unit must be 
installed vertically in the piping. 

 

Ensure that filter is installed without any stresses. 

 

Use original spare parts only. 

 

Use the device for appropriate purpose only. 

 

There shouldn’t be any tension between filter and installation. Filter shouldn’t be subject 
to any stress, vibration or other influence that could cause damage to the unit. 

 

 

Summary of Contents for WFIf

Page 1: ...and operating manual WFIf Please read the following instructions carefully before installing filter housing unit into service Trouble free and safe operating of the unit can only be guaranteed if rec...

Page 2: ...WFIf Installation and operating manual 2 Components Part 1 Filter head 2 Sealing 3 Filter element 4 Filter bowl 5 Nut 3 2 1 4 5...

Page 3: ...6720 3 955 1288 410 456 219 1 1 43 64 WFIF 900 DN150 4X3030 10 9600 5 650 1310 480 273 0 1 77 87 WFIF 1200 DN150 6X3030 10 13440 7 910 1351 540 598 323 9 1 104 110 WFIF 1800 DN200 8X3030 10 17280 10...

Page 4: ...tegory 2 Module H WFIf 240 900 Category 3 Module H WFIf 1200 2000 Category 4 Module H1 PRESSURE EQUIPMENT DIRECTIVE PED 2014 68 EU Fluid group 2 WFIF 010 070 Article 4 3 WFIF 094 200 Category 1 Module...

Page 5: ...to ensure that the unit is equipped with the corresponding safety and test devices to prevent the permissible operating parameters from being exceeded Filter has been designed for a primarily static...

Page 6: ...are to be considered incorrect Specifically filter is not intended for human breathing without proper additional equipment Warning internal corrosion can seriously reduce the safety of installation c...

Page 7: ...WFIf Installation and operating manual 7 Installation For oil removal coalescing filter element must be installed Flow direction inside out must be provided 1 2 3 4 5 6 7 8 9 10 11 12...

Page 8: ...eplace filter element with new one Replace PP PR PM PS filter at least element every 12 months or when pressure drop reaches 350 mbar Replace PA filter element at least every 6 months The housing O ri...

Page 9: ...ng and maintenance The unit was not operated properly and appropriately The unit was operated when it was clearly defective Non original spare parts or replacement parts were used The unit was not ope...

Page 10: ...Installation and operating manual 10 OMEGA AIR d o o Ljubljana Cesta Dolomitskega odreda 10 SI 1000 Ljubljana Slovenia Tel 386 0 1 200 68 00 Fax 386 0 1 200 68 50 E mail info omega air si www omega ai...

Reviews: