OMEGA AIR TD 420M Installation And Operating Manual Download Page 6

 

 

3.

 

Safety instructions 

 

 

Depressurize the system before carrying out any work on the piping. 

 

Installation and maintenance work may only be carried out when the device is not under 
pressure. 

 

Installation and maintenance work may only be carried out by trained and experienced 
personnel. 

 

Installation and maintenance work may only be carried out when electrical power supply is 
disconnected. 

 

Electrical work must always be carried out by qualified electrician. 

 

Do not exceed maximal operating pressure or operating temperature range (see data label). 

 

Do not use the device in hazardous areas with potentially explosive atmospheres. 

 

Use original spare parts only. 

 

Use the device for the appropriate purpose only. 

3.1

 

Hazardes classes 

Important instructions regarding personal protection and safe operation are indicated in the manual 
in distinct hazard classes. The hazard classes explain how states or individual steps of an operation 
sequence are dangerous and can cause damage. 

Hazard class 

Description 

DANGER 

Indication of an immediate imminent danger. If the warning is not observed, this 
will result in death or serious injuries. 

WARMING 

Indication of a potentially dangerous situation. If the warning is not observed, this 
can result in death or serious injuries. 

CAUTION 

Indication of a potentially dangerous situation. If the warning is not observed, this 
can result in minor injuries. 

NOTICE 

Indicate of a potentially dangerous situation. If the waning is not observed, this can 
result in material damage. 

 

3.2

 

Structure of the warning 

The warnings describe the type and source of danger, the consequences of not heeding these 
warnings, and measures to be taken to avert danger. A warning is always structured according to the 
following pattern: 

 

Type and source of danger. 

Consequences of not heeding the warning. 

 

Measures for averting the danger. 

 

 

 

Summary of Contents for TD 420M

Page 1: ...ease read the following instructions carefully before installing the product Trouble free and safe operating of the product can only be guaranteed if recommendations and conditions stated in this manu...

Page 2: ...fluids 5 2 5 Types 5 2 6 Order number 5 3 Safety instructions 6 3 1 Hazardes classes 6 3 2 Structure of the warning 6 4 Appropriate use 7 5 Installation 7 6 Storage information 9 7 Operation 10 7 1 In...

Page 3: ...3 1 Components 1 Nipple 2 High pressure needle valve 3 Elbow 4 Electromagnetic valve 5 Connector gasket 6 Timer...

Page 4: ...Connector DIN EN 175301 803 form A Time ON 0 5s 10s Time OFF 0 5min 45min Indicator LED light 3 Standard version TD420M 230V AC 4 Version TD420M 24V DC only up to a pressure 400 bar g 5800 psi 2 2Part...

Page 5: ...z 8W 420 6091 Air water oil 0 3 TD420M 115V AC 115V AC 50 60Hz 16W 420 6091 Air water oil 0 3 TD420M 24V DC 5 24V DC 18W 400 5800 Air water oil 0 3 5 Version TD420M 115V AC have on housing of electrom...

Page 6: ...e manual in distinct hazard classes The hazard classes explain how states or individual steps of an operation sequence are dangerous and can cause damage Hazard class Description DANGER Indication of...

Page 7: ...essure could be dangerous and hazardous to the operator Before installing the device check that the system is not under pressure Wear necessary personal protective equipment and keep follow the safety...

Page 8: ...alve 2 with elbow 3 See picture on page 7 There can also use a seal You must follow the arrows on valves from inlet pointing to the outlet 3 Then is needed to connect a second nipple 1 with elbow 3 Th...

Page 9: ...careful not to pinch wires by cover Be careful to clamp all strains of wires into respective terminal blocks use ferrules Electrical connection should be made as shown above It depends on orientation...

Page 10: ...system to condensate drain 2 Outlet from condensate drain to condensate collecting pipeline Condensate drain consists of two timers Ton and Toff The Ton timer regulates the time duration of dischargi...

Page 11: ...ing it is switched off 7 1Inlet valve The function of inlet valve is that you can make a service on condensate service or that you can replace it Inlet valve must be full open during operation Risk of...

Page 12: ...e ball valve 2 Depressurize the unit push test button 3 Cut off the power supply Once per week make a visual check of the fittings and valve with timer controller Next to a visual check we must do tim...

Page 13: ...ions when disposing 3 Waste separation Metallic components to be turned into scrap metal plastic parts should be recycled lubricants and other auxiliary materials are subject to the provisions regardi...

Page 14: ...14 OMEGA AIR d o o Ljubljana Cesta Dolomitskega odreda 10 SI 1000 Ljubljana Slovenia T 386 0 1 200 68 00 F 386 0 1 200 68 50 info omega air si...