OMEGA AIR TD 420M Installation And Operating Manual Download Page 13

13 

 

 

10.

 

Disposing  

 

Environmental damage in case of faulty disposal!

 

The device might be contaminated by the filtered substances. 

1.

 

Be mindful of the local regulations. 

2.

 

Heed the notes on hazardous substances for the filtered gas and appropriate disposal 
regulations when disposing. 

3.

 

Waste separation! 

 

Metallic components to be turned into scrap metal, 

 

plastic parts should be recycled, 

 

lubricants and other auxiliary materials are subject to the provisions regarding 
the treatment of special refuse, 

 

dispose of the remaining components after sorting them with respect to the 
nature of the materials. 

4.

 

The type plate is to remove mechanically. 

5.

 

Ensure that materials are only disposed of by licensed specialised companies. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for TD 420M

Page 1: ...ease read the following instructions carefully before installing the product Trouble free and safe operating of the product can only be guaranteed if recommendations and conditions stated in this manu...

Page 2: ...fluids 5 2 5 Types 5 2 6 Order number 5 3 Safety instructions 6 3 1 Hazardes classes 6 3 2 Structure of the warning 6 4 Appropriate use 7 5 Installation 7 6 Storage information 9 7 Operation 10 7 1 In...

Page 3: ...3 1 Components 1 Nipple 2 High pressure needle valve 3 Elbow 4 Electromagnetic valve 5 Connector gasket 6 Timer...

Page 4: ...Connector DIN EN 175301 803 form A Time ON 0 5s 10s Time OFF 0 5min 45min Indicator LED light 3 Standard version TD420M 230V AC 4 Version TD420M 24V DC only up to a pressure 400 bar g 5800 psi 2 2Part...

Page 5: ...z 8W 420 6091 Air water oil 0 3 TD420M 115V AC 115V AC 50 60Hz 16W 420 6091 Air water oil 0 3 TD420M 24V DC 5 24V DC 18W 400 5800 Air water oil 0 3 5 Version TD420M 115V AC have on housing of electrom...

Page 6: ...e manual in distinct hazard classes The hazard classes explain how states or individual steps of an operation sequence are dangerous and can cause damage Hazard class Description DANGER Indication of...

Page 7: ...essure could be dangerous and hazardous to the operator Before installing the device check that the system is not under pressure Wear necessary personal protective equipment and keep follow the safety...

Page 8: ...alve 2 with elbow 3 See picture on page 7 There can also use a seal You must follow the arrows on valves from inlet pointing to the outlet 3 Then is needed to connect a second nipple 1 with elbow 3 Th...

Page 9: ...careful not to pinch wires by cover Be careful to clamp all strains of wires into respective terminal blocks use ferrules Electrical connection should be made as shown above It depends on orientation...

Page 10: ...system to condensate drain 2 Outlet from condensate drain to condensate collecting pipeline Condensate drain consists of two timers Ton and Toff The Ton timer regulates the time duration of dischargi...

Page 11: ...ing it is switched off 7 1Inlet valve The function of inlet valve is that you can make a service on condensate service or that you can replace it Inlet valve must be full open during operation Risk of...

Page 12: ...e ball valve 2 Depressurize the unit push test button 3 Cut off the power supply Once per week make a visual check of the fittings and valve with timer controller Next to a visual check we must do tim...

Page 13: ...ions when disposing 3 Waste separation Metallic components to be turned into scrap metal plastic parts should be recycled lubricants and other auxiliary materials are subject to the provisions regardi...

Page 14: ...14 OMEGA AIR d o o Ljubljana Cesta Dolomitskega odreda 10 SI 1000 Ljubljana Slovenia T 386 0 1 200 68 00 F 386 0 1 200 68 50 info omega air si...