Troubleshooting 

After powering EMD, it enters overload mode and afterwards, it enters alarm mode.  

During power down, large amount of condensed water has collected in compressed air system. Hold the 

test button until all the water is drained. 

EMD enters alarm mode occasionally. But, it gets back to normal mode immediately after all the water is 

drained by holding the test button.  

The reason might be extremely hot and moist day. 
EMD is undersized and it should be replaced by bigger drain. 

Pressing test button does not open the valve.  

Check electric power and cable connections.  
Check the fuse.  

There is no LED signal although the valve could be opened by pressing test button.  

The LED is not bright enough to be seen in daylight.  

Fuse is blown.  

Check integrity of electronics. Replace the fuse if there is no visible damage on electronics. 

Air leaks through the drain pipe even when EMD is disconnected from power.  

There might be debris in valve or valve may be damaged. Check integrity of strainer. The valve assembly 

should be cleaned or replaced by authorized person.  

Long flashes of green LED indicate full tank although the tank is empty.  

Clean the water level sensor surface.  

EMD is in alarm and there is no water drained, only air.  

Clean the water level sensor surface.  

EMD is in alarm and valve opens, but there is no water or air drained.  

Path between EMD’s tank and valve is clogged. Clean the tank, strainer and valve assembly. Replace 

strainer or valve assembly when they are damaged. 

Condensed water is not drained automatically. Instead, it is drained only when test button is pressed.  

If the amount of drained water is small, then the water in tank hasn’t reached the threshold, yet.  
If water is drained during pressing the test button, then we should check the piping in front of EMD. 

Pipe’s inclination is too small or there may be debris in the pipe so that air in the EMD’s tank is trapped. 

When the test button is pressed, this air escapes through drainage and makes place for condensed 

water. Solution: clean pipe, build venting. Switch timer function on. 

Red LED is flashing.  

EMD is in one of production modes or there is some other error.  First, check supply voltage. Then, 

contact supplier. 

Summary of Contents for EMD HP

Page 1: ...tions carefully before installing filter into service Trouble free and safe operating of the filter can only be guaranteed if recommendations and conditions stated in this manual are respected Install...

Page 2: ...parts are intercepted The bottom can be removed from EMD HP for cleaning In the condensed water leaving the EMD HP there are still small particles of rust and remains of compressor oil Oil must be rem...

Page 3: ...venting mode the valve is opened after the venting period has expired and trapped air is allowed to escape through drainage Now condensed water can reach water level sensor and EMD HP is opening its...

Page 4: ...ng 100 x 1 5 9 Power Inlet gland 10 Sealing O Ring 12 x 2 0 11 Alarm inlet plug 12 Valve 13 Flow choke 14 Bracket 15 Washer 5 3 DIN125A 16 Screw M4x8 DIN912 17 Sealing O Ring 54 x 3 0 18 Back up ring...

Page 5: ...22W Operating pressure range 0 50 bar 0 725 psi Drain capacity Kv 30 4 l h 50 bar 0 018 cfm 725 psi 4 3 l h bar Operating temperature range 1 5 C 65 C Protection class IP 54 Inlet connection G 1 2 par...

Page 6: ...ly be carried out when electrical power supply is disconnected Electrical work must always be carried out by qualified electrician Do not exceed maximal operating pressure or operating temperature ran...

Page 7: ...enance takes place The outlet of EMD HP s valve is connected to drainage system by suitable connection and pipe Pay attention that in case of clogged drainage pressure in it would rise up to the syste...

Page 8: ...l drainage pipes must be inclined so that air could escape from EMD HP and that debriss is flushed toward EMD HP left When horizontal drainge pipes are long venting should be built right Electrical wi...

Page 9: ...7V Power Connection 1 24Vac grounded line 2 24Vac 3 PE Conductor Valve Connection 4 PE Conductor 5 Power line 6 Power line Alarm output EMD HP A 7 Alarm Warning 9 GND Umax at high impedance 39V Imax...

Page 10: ...device of heavy inductive load like compressor motor left Instead heavy inductive load and EMD HP should be protected separately right After installation or maintenance work press the test button to d...

Page 11: ...its valve longer and more frequently and its capacity is doubled When EMD HP is still not able to discharge all the water in 5min it enters alarm mode In alarm mode EMD HP opens its valve so that it w...

Page 12: ...twork Reader SN 10 200 It s a handheld device that allows user to send command messages manually It also comprises a display where answer to command are read In the table in next page command message...

Page 13: ...ensor adjustment data 0xC0 Current working parameters 0xE0 0xF0 Settings 0xE4 Timed Venting valve opened period Values 0 6s 0 8s 1 2s 1 7s 2 4s Timed venting off default 0xE8 Timed Venting Period to f...

Page 14: ...s integrity Clean also O ring sealing and its gland thoroughly Otherwise strainer sealing may start to leak Be careful while cleaning because solid particles in debris may be sharp Reattach bottom cov...

Page 15: ...r The valve assembly should be cleaned or replaced by authorized person Long flashes of green LED indicate full tank although the tank is empty Clean the water level sensor surface EMD is in alarm and...

Page 16: ...n The guarantee shall be void if The installation and operating manual was not followed with respect to installation initial commissioning and maintenance The unit was not operated properly and approp...

Reviews: