Trouble shooting
Warranty exclusion
The guarantee shall be void if:
The installation and operating manual was not followed with respect to installation,
initial commissioning and maintenance.
The unit was not operated properly and appropriately.
The unit was operated when it was clearly defective.
Non-original spare parts or replacement parts were used.
The unit was not operated within the permissible technical parameters.
Unauthorized constructional changes were made to the unit or if the unit has been
opened/disassembled by an unauthorized person.
OMEGA AIR d.o.o. Ljubljana
Cesta Dolomitskega odreda 10
SI-1000 Ljubljana, Slovenia
Tel.: +386 (0)1 200 68 00
Fax.: +386 (0)1 200 68 50
E-mail: [email protected]
www.omega-air.si
Problem
Possible cause
Solution
LED lights on
CDi-16B don`t
light up
System initialisation is not
performed
Power cut
Voltage is not the same as
declared for CDi-16B
Presence of voltage, time for
initialisation passed by
After connection wait 2 sec for system initialisation
Check for voltage in circuit
Check the cable and power connection
Connect CDi-16B to proper voltage
Mistake must be repaired by authorised
representative
CDi-16B
discharges
condense water
few times one
after another
Condense water discharge is
partially or completely
stopped
There`s no pressure in the
system
Valve cannot be opened
There`s a lot of dirtiness on a
probe
Clean condense water discharge including
discharge pipe
Check for possible freezing and unfreeze parts
Assure compressed air pressure
Clean the valve seat
Clean a probe
Mistake must be repaired by authorised
representative
CDi-16B doesn`t
discharge
condense water
Critical condense water level
is not exceeded
Disconnected or faulty
connected probe to
electronics or faulty PCB
Check if the device is clean and no dirt is blocking
the valve.
Check if air vent is needed
Error must be repaired by authorised
representative
CDi-16B is in
alarm mode
(red LED signal)
The device was not able to
discharge all the condensate
for longer period of time
Check if the device is dimensioned correctly (max.
condensate capacity = 45 l/h)
Clean the device