Trouble shooting 

 

 

Warranty exclusion 

 

The guarantee shall be void if: 

 

The installation and operating manual was not followed with respect to installation, 
initial commissioning and maintenance. 

 

The unit was not operated properly and appropriately. 

 

The unit was operated when it was clearly defective. 

 

Non-original spare parts or replacement parts were used. 

 

The unit was not operated within the permissible technical parameters. 

 

Unauthorized constructional changes were made to the unit or if the unit has been 
opened/disassembled by an unauthorized person. 

 

OMEGA AIR d.o.o. Ljubljana 

Cesta Dolomitskega odreda 10 

SI-1000 Ljubljana, Slovenia 

Tel.: +386 (0)1 200 68 00 

Fax.: +386 (0)1 200 68 50 

E-mail: [email protected] 

www.omega-air.si 

Problem 

Possible cause 

Solution 

 LED lights on 

CDi-16B don`t 

light up 

 

System initialisation is not 
performed 

 

Power cut 

 

Voltage is not the same as 
declared for CDi-16B 

 

Presence of voltage, time for 
initialisation passed by 

 

After connection wait 2 sec for system initialisation  

 

Check for voltage in circuit 

 

Check the cable and power connection 

 

Connect CDi-16B to proper voltage 

 

Mistake must be repaired by authorised 
representative 

CDi-16B 

discharges 

condense water 

few times one 

after another 

 

Condense water discharge is 
partially or completely 
stopped  

 

There`s no pressure in the 
system 

 

Valve cannot be opened 

 

There`s a lot of dirtiness on a 
probe 

 

Clean condense water discharge including 
discharge pipe 

 

Check for possible freezing and unfreeze parts 

 

Assure compressed air pressure 

 

Clean the valve seat 

 

Clean a probe 

 

Mistake must be repaired by authorised 
representative 

CDi-16B doesn`t 

discharge 

condense water 

 

Critical condense water level 
is not exceeded 

 

Disconnected or faulty 
connected probe to 
electronics or faulty PCB 
 

 

Check if the device is clean and no dirt is blocking 
the valve. 

 

Check if air vent is needed 

 

Error must be repaired by authorised 
representative 

CDi-16B is in 

alarm mode 

(red LED signal) 

 

The device was not able to 
discharge all the condensate 
for longer period of time 
 

 

Check if the device is dimensioned correctly (max. 
condensate capacity = 45 l/h) 

 

Clean the device 

Summary of Contents for CDi-16B

Page 1: ...tion and operating manual CDi 16B Please read the following instructions carefully before installing electronic drain unit into service Trouble free and safe operating of the unit can only be guarante...

Page 2: ...ng 21 95x1 78 4 Damper 14 Screw plug 1 2 24 Screw PT KA 35x16 34 Screw KA 30x8 5 Valve housing 15 Connection Al 50 25 Foil keyboard 35 Screw KA 30x8 6 Plunger 16 Fixing screw 1 8 26 O ring 38 0x3 0 36...

Page 3: ...5 C 35 to 149 F Upper Inlet connection G 1 2 BSP Lower Inlet connection G 1 2 BSP Outlet connection G 1 8 BSP Power interface 3 x 0 5mm 2 Protection class IP65 Volume 0 1 l Mass 0 96 kg Dimensions A x...

Page 4: ...abel Do not use the device in hazardous areas with potentially explosive atmospheres Use original spare parts only Use the device for the appropriate purpose only Appropriate use CDi 16B series electr...

Page 5: ...gnal to electronic board Electromagnetic valve 4 is than opened to discharge accumulated condensate through outlet connection 5 When reservoir 2 has been emptied the valve 4 closes back without any lo...

Page 6: ...commended Install ball valves 2 only Recommended connection 4 to water oil separator 1 2 The inclination of the unit must not exceed 5 in both axes If device is not installed correctly it could cause...

Page 7: ...ped air prevents the condensate being purged from drain 5 During installation ensure that no water pockets are formed in the piping 6 7 8 When drainage is to take place directly from a pipeline it is...

Page 8: ...11 Warning Upper and back connections cannot be used as condensate inlet at the same time 13 14 STANDARD INSTALLATION Upper connection Inlet Back connection Closed VENTING LINE INSTALLATION Upper con...

Page 9: ...ctions LED indicator TEST button LED indicator LED indicates device condition 1 Green ON Power on reservoir empty waiting condensate to accumulate 2 Green FLASHES Device is discharging condensate 3 Re...

Page 10: ...osed for one second This cycle repeats for five minutes up to 100 discharges In case the reservoir empties during overload mode device enters normal mode again ALARM If drain was still not able to dis...

Page 11: ...nce work take the drain out of operation switch off the power supply and depressurize the unit Service kits Based on type of CDi 16B drain following servis kits can be used SERVIS KIT CDI 16 B 230V SE...

Page 12: ...lisation passed by After connection wait 2 sec for system initialisation Check for voltage in circuit Check the cable and power connection Connect CDi 16B to proper voltage Mistake must be repaired by...

Reviews: