40
8 Storage
In order to prevent the damage to the dryer during storage make sure that the following
requirements are fulfilled:
•
Dryer can only be stored at a dry and clean indoor location.
•
During storage ambient temperature must not exceed 1,5°C – 66°C range. For other
storage temperatures please contact the manufacturer.
•
Make sure that the inlet and the outlet to the dryer are closed with a plug.
In case you intend to store the dryer which has been in operation follow the procedure
specified below:
•
Close the outlet valve.
•
Make sure the dryer is in FIX operating mode.
•
Leave the dryer to operate for a while (min. 4h).
•
Close the inlet valve.
•
Decommission the dryer.
•
Depressurize the dryer. The dryer should get fully depressurized in one cycle.
•
Disconnect the dryer from electric power supply.
•
Disconnect the dryer from piping installation.
•
Close inlet and outlet of the dryer with plugs.
•
Use appropriate cover to protect the dryer from the dust.
Summary of Contents for B-DRY 1000
Page 2: ...2...
Page 15: ...15...
Page 31: ...31 5 10 Electrical Scheme Sensor Connection...
Page 35: ...35...
Page 37: ...37 Enter the password and you will get access to the controller interface...
Page 61: ...61 15 Maintenance Record TYPE OF MAINTENANCE DATE SIGNATURE NOTES Commissioned...
Page 62: ...62...
Page 63: ...63...
Page 64: ...64...