12
TECHNICAL PARAMETERS
Operating pressure
4 – 16 bar
Operating temperature
1,5°C to 60°C
Pressure dew points
-40°C (-25, -70)
Voltage, Frequency
230V, 50/60Hz
Power consumption
<60W
Protection class (controller)
IP 65
Noise level (at 1m distance)
Normally up to 100dB(A)
Filter (inlet)*
Super fine coalescing; residual oil cont. <0,01mg/m3;
0,01µm
Filter (outlet)
Dust filter; 1µm
Input for stand-by
STANDARD
Dew point dependent control
OPTIONAL
*If dryer is supplied without inlet filter compressed air class 1 (ISO 8753-1) for solid particles and oil should be
provided to the inlet of the dryer.
DRYER RATING ACCORDING TO ISO8573-1
Solid particles
(1)
Water
(1),(2)
Oil
(1)
2
1-3
1
(1)
Typical result based on standard configuration and nominal operating conditions
(2)
Depending on the specific design, class 2 when operated at nominal operating conditions.
MATERIALS
Columns, construction, support
Steel
Column inner protection
/
Column and construction outer protection
Epoxy painted
Desiccant support screen (strainer)
Stainless steel
Valves
Brass, aluminium
Sealings
NBR
Fittings, Screws, plugs
INOX, brass, steel (zinc plated)
Lubricant
Shell cassida grease RLS 2
Outside protection
Powder paint coated (Epoxy-polyester base)
Desiccant
80% Molecular sieve 4A, 20% Silica gel
PRESSURE EQUIPMENT DIRECTIVE
PED 2014/68/EU (Fluid group 2)
B-DRY 110 to B-DRY 300
Category 2, Module H
B-DRY 400 to B-DRY 1000
Category 3, Module H
Summary of Contents for B-DRY 1000
Page 2: ...2...
Page 15: ...15...
Page 31: ...31 5 10 Electrical Scheme Sensor Connection...
Page 35: ...35...
Page 37: ...37 Enter the password and you will get access to the controller interface...
Page 61: ...61 15 Maintenance Record TYPE OF MAINTENANCE DATE SIGNATURE NOTES Commissioned...
Page 62: ...62...
Page 63: ...63...
Page 64: ...64...