Installation 

 

 

Warning 

Before installing the device, check that the system is not 
under pressure. Wear necessary personal protective 
equipment and keep folow the safety rules when working 
with pressure equipment. 

 

 

Before connecting the drain, blow compressed air through the piping in order to 
thoroughly clean out any impurities within it. 

 

Install the AOK 20SS at a level below the receiver, if not the receiver will fill up with 
condensate. 

 

It is recommended to install a ball valve between the device and the system. This is 
done to ensure easy maintenance work on the device without the needed to empty 
the entire system. In addition to the ball valve it is also recommended to add 
strainer, and then the nipple tubing (17) to allow the flow of air upward.  

 

After initial run, open AOK 20SS and clean all components. 

 

It is strongly recommended that waste condensate from discharge port is connected 
to water treatment application, such as WOSm series water oil separator to protect 
the environment from pollution and to comply with environmental laws. 

 

 

 

 

Summary of Contents for AOK 20SS

Page 1: ...al Please read the following instructions carefully before installing the product Trouble free and safe operating of the product can only be guaranteed if recommendations and conditions stated in this...

Page 2: ...ing sealing 5 1x Float holder 6 1x Nozzle 7 1x Flat seal 8 1x Housing 9 1x Plug 10 1x Test button 11 1x O ring sealing 12 1x Lever holder 13 1x Circlip external 14 1x M4 screws 15 1x Lever 16 1x Float...

Page 3: ...ling NBR Operation pressure range 0 20 bar 0 290 psi Minimum reccomended operating pressure 1 5bar g 21 8 psi Drain capacity 7 bar 101 psi 167 l h 0 1 scfm Drain capacity 16 bar 235 psi 252 l h 0 15 s...

Page 4: ...data label Do not use the device in hazardous areas with potentially explosive atmospheres Use original spare parts only Use the device for the appropriate purpose only Appropriate use AOK 20SS serie...

Page 5: ...nection When condensate level drops floater drops with it and blocks the discharge orifice This operation prevents air loss On the front side of the AOK 20SS is a TEST button which if rotated in a clo...

Page 6: ...with condensate It is recommended to install a ball valve between the device and the system This is done to ensure easy maintenance work on the device without the needed to empty the entire system In...

Page 7: ...nded to clean the reservoir at least once a year Sealing elements are subject to wear which depends on various operating parameters such as pressure temperature dirt content etc It is also recommended...

Page 8: ...8 OMEGA AIR d o o Ljubljana Cesta Dolomitskega odreda 10 SI 1000 Ljubljana Slovenia Tel 386 0 1 200 68 00 Fax 386 0 1 200 68 50 E mail info omega air si www omega air si...

Reviews: