AOK 20SS - Installation and operating manual 

 

 

Operating 

 

 

 

Drain is installed bellow pressure vessel, filter element, dryer, cyclone separator or similar 
pressure system element. Through connection on the top condensate accumulates in the 
drain reservoir. Increasing water level rise the floating buoyancy. When the condensate level 
is high enough the floater unblocks the discharge orifice and the condensate is purged out 
through output connection. When condensate level drops floater drops with it and blocks 
the discharge orifice. This operation prevents air loss. 

On the front side of the AOK 20SS is a TEST button, which if rotated in a clockwise direction 
they lifts the float, which opens the outlet and drains the condensate. This can be done at 
any time. The button can also be used as a release of pressure from the system. But for 
longer release times of compressed air from the system, we recommend disconnecting all 
devices from the OUTLET connection, such as traps, oil separators, piping, ...  

   

It is forbidden to use force or other tools to rotate the test button.

 

Test ON/OFF 

Summary of Contents for AOK 20SS

Page 1: ...al Please read the following instructions carefully before installing the product Trouble free and safe operating of the product can only be guaranteed if recommendations and conditions stated in this...

Page 2: ...ing sealing 5 1x Float holder 6 1x Nozzle 7 1x Flat seal 8 1x Housing 9 1x Plug 10 1x Test button 11 1x O ring sealing 12 1x Lever holder 13 1x Circlip external 14 1x M4 screws 15 1x Lever 16 1x Float...

Page 3: ...ling NBR Operation pressure range 0 20 bar 0 290 psi Minimum reccomended operating pressure 1 5bar g 21 8 psi Drain capacity 7 bar 101 psi 167 l h 0 1 scfm Drain capacity 16 bar 235 psi 252 l h 0 15 s...

Page 4: ...data label Do not use the device in hazardous areas with potentially explosive atmospheres Use original spare parts only Use the device for the appropriate purpose only Appropriate use AOK 20SS serie...

Page 5: ...nection When condensate level drops floater drops with it and blocks the discharge orifice This operation prevents air loss On the front side of the AOK 20SS is a TEST button which if rotated in a clo...

Page 6: ...with condensate It is recommended to install a ball valve between the device and the system This is done to ensure easy maintenance work on the device without the needed to empty the entire system In...

Page 7: ...nded to clean the reservoir at least once a year Sealing elements are subject to wear which depends on various operating parameters such as pressure temperature dirt content etc It is also recommended...

Page 8: ...8 OMEGA AIR d o o Ljubljana Cesta Dolomitskega odreda 10 SI 1000 Ljubljana Slovenia Tel 386 0 1 200 68 00 Fax 386 0 1 200 68 50 E mail info omega air si www omega air si...

Reviews: