AOK 13PA - Installation and operating manual
3
Technical data
CALCULATION OF CAPACITY
For rough calculation of discharge capacity at certain pressure use following equation:
𝑄 = 63√∆𝑝
Example: if operating at 7barg;
𝑄 = 63√7 = 166,7
MATERIALS
Housing material
Plastic (PA 6 30GF)
Fittings, Screws
Brass, Brass-zinc plated, Steel
Floater
Stainless steel 1.4301
Sealing
NBR
Operation pressure range
0
–
13 bar
0
–
188 psi
Minimum recommended operating
pressure
1,5bar (g)
21,8 psi
Drain capacity (7 bar / 101 psi)
167 l/h
0,1 scfm
Drain capacity (13 bar / 188 psi)
226 l/h
0,13 scfm
Operating temperature range
1,5
–
50°C
35 -
122 °F
Operating media
Condensate (air, water, oil); Non-aggressive
Inlet connection
G ½”
Outlet connection
G ½”
Reservoir volume
0,4 l
Mass
0,5 kg
Dimensions A x B x C [mm]
115 x 141 x 122
Dimensions with nipple D x E [mm]
198 x 58
Valve type
Direct acting, Normally closed
Discharge orifice cross section
1,8mm
0,0708 inch