Operation
NEW TYPE INSTRUCTIONS
Turn on the power supply, long press the “SET” to enter the memory function, there will “P0” to “P9” showed
on the screen which means enter the memory setting mode, each time the “SET” is pressed which means
to switch the preset parameter template, select P0 parameter template long press the “SET” to enter the P0
parameter template, press the “SEALING TEMPERATURE” to switch the sealing temperature, after that press
the “SET” to set the vacuum, sealing and cooling time. Press the “SET” to return to the standby state. The
complete process of parameter preset.
OLD TYPE INSTRUCTIONS
•
Turn on the power supply and select a suitable vacuum packing bag for the product.
•
Set the processing parameter and select the sealing temperature.
•
Place the vacuum bag at the chamber with the opening end on top of the sealing bar. Clamp it with the
hook provided.
•
Close the acrylic cover and the machine will complete the processing procedure automatically.
•
During processing, the vacuum chamber will form a vacuum self-lock state, the whole heating and sealing
procedure are completed in a vacuum environment, and the LED display on panel shows the flow process.
• When the vacuum indicator on panel lights, the equipment is under vacuum state, the LED display shows
the vacuum time, and it will enter into the next work state automatically after the timing is finished.
• When the heating indicator lights, the equipment enters into heating work state, and the panel shows the
reverse timing of heating. It will enter into cooling state automatically after the timing is finished.
• According to the time setting, the machine doesn’t act when cooling, the panel shows “□□” till the reverse
timing is finished, air is returned, the cover opens automatically, and the whole processing is finished. Then
prepare the next cycle.
• Press the E-Stop Button for a sudden condition under processing state, the machine will go to return-air
action automatically, the cover opens automatically after return-air action, so the processing ends.
NOTES:
•
Silicone rubber strip come with one side nerving and the other for letter and number inserting. It will have
embossed effect on sealing surface.
•
Please do not run the machine without any vacuum bag attached. Otherwise, the heating element will have
higher wear and tear.
• Cut off the power supply and disconnect the plug when not in use.
• The vacuum gauge/meter reading may be different due to different environments. At higher altitudes, the
data in the vacuum meter will be lower.
•
Please adopt suitable cooling measure when processing is done in a high temperature occasion.
•
Please use the vacuum bag whose material does not bring any poisonous gas in the sealing.
•
The machine should be placed horizontally in the transportation. The transportation must be proceeded
strictly according to the instructing marks on the shipping case.
•
The machine should be stored in a dry, ventilated, normal temperature location.
• Mind your head when the lid opens, avoid the lid striking your head.
• Please ask Omcan when requiring troubleshooting, do not attempt repairs by yourself.
IMPORTANT INFORMATION ABOUT COOLING: THE COOLING TIME MUST BE SET AT LEAST 1