![Omcan VP-CN-0600 Instruction Manual Download Page 6](http://html1.mh-extra.com/html/omcan/vp-cn-0600/vp-cn-0600_instruction-manual_4163247006.webp)
6
Installation
precautions.
• You must fill the vacuum pump with NO.68 or NO.100 vacuum pump oil before use. When running, the oil
level should not be lower than 1/3 height of oil window. Do not fill beyond the 1/2 mark.
•
The machine should be placed horizontally in good ventilation without corrosive gas and heavy dust.
• The power connection position may be located on a different side, so be sure to do grounding protection
before use.
•
Always ensure the top cover is open before turning the power on. Start the machine by pressing the top
cover and the process will start automatically.
• Preheating of vacuum pump must be done in a low temperature working area. Turn off the heater selection
switch at the control panel to off position. This is to prevent heating process and to cut down wear and tear
of the unit. Run the vacuum pump a few time and machine will be ready to use.
SETTINGS
Please set every parameter first before starting the machine.
•
Turn on the power supply, check through the settings on the panel and make sure “------” must be shown
after setting is done. Otherwise, operation of this machine will not work if the setting is not on this mode.
•
Press the setting button, the indicator lamp of the unit will light to enter into the setting state of vacuum
timing. Press the upward or downward key to increase or decrease vacuum time in the range of 0-99
seconds.
•
Press the parameter set key, the heating indicator lamp lights up to enter into the heating setting state.
Press the upward or downward key to increase or decrease the heating sealing time in the range of 0-3.5
seconds.
•
After the heating time is set, press the set key again, the cooling indicator lamp lights up to enter into the
setting state of cooling time in the range of 0-9.9 seconds.
• After the cooling time is set, press the set key again to finish the parameter setting, and “Ed” is shown in
the panel.
•
Press the “temperature selection” set key to enter into temperature set state. Press the set key once,
indicate one corresponding temperature value, and the lamp shows an orange color; there are three
selections such as “high temperature”, “middle temperature” and “low temperature”.
REMARKS & TIPS
Ways to quickly process a small item or product using a bigger chamber is to place a solid block into the
chamber as to allow less vacuum time needed due to compact space.
IMPORTANT: DO NOT BLOCK THE AIR HOLE IN THE CHAMBER