10
Troubleshooting
Maintenance
FAULT FINDING
First identify exactly why the machine stopped.
The machine will not start:
• Check:
the mains power supply and the condition of the power supply cord,
• Check:
the position of the juice bowl (4) on the bowl centering device (7), the position of the cover (2) on
the juice bowl, and the locking of the clamping handle (1).
The machine stops because the motor has overheated:
(the metal casing around the motor unit is hot)
• Remove the plug from the power supply socket and follow the instructions in the section on "motor
overheating safety feature".
The machine stops because of an overload:
• See the section on "motor overload safety feature".
The machine vibrates when running empty:
This vibration is caused by an imbalance. This imbalance may be caused by:
• The basket (5) being positioned incorrectly: check it is correctly positioned
• Distortion of the basket (5), check and replace if necessary.
REFERENCE
Item Number Model Number
Description
Manufacturer Model Number
39684
Santos 68
Juice Extractor 140 L / 37 Gal per Hour
with EZY Clean 1.75 HP / 1300 W
110V/60/1 NSF cULus
68V1
SAFE ACCESS TO THE TOOLS:
• The juice extractor can only be started if the cover and bowl are positioned correctly on the bowl centering
device (7) and the clamping handle (1) is locked.
• Releasing the clamping handle (1) results in the machine stopping and the immobilization of the rotating
elements in less than 3 seconds.
• Re-starting the juice extractor requires specific operation of the On switch (11) again.
• A cut in the mains power supply makes the machine stop.