12
Controller Instructions
Table of Functions activated by the buttons - Models S, X, Y, C (Table 2)
Button
Normal Operation
Start Up
Pressing the Button Alone Pressed Together
Up
ON/OFF
More than 3 sec: toggle ON/
OFF
Start/Stop
continuous cycle
-
Down
Defrost
More than 3 sec: start/stop
defrost
Pressed
together
Start parameter
reset procedure
For 1 sec.
display
firmware
vers. code
Set Mute - 1 sec.: display/set the set
point.
- more than 3 secs.: access
parameter setting menu
(enter password )
- mute audible alarm
(buzzer)
-
For 1 sec.
RESET cur-
rent EZY set
Setting the set point (desired temperature)
• press
SET
for 1 sec, the set value will start flashing after a few moments;
• increase or decrease the value using
UP
or
DOWN
;
• press
SET
to confirm the new value.
Switching the device ON/OFF
Press
UP
for more than 3 sec. The control and defrost algorithms are now disabled and the Instrument
displays the message “OFF” alternating with the temperature read by the set probe.
Manual defrost
Press for
DOWN
more than 3 sec (the defrost starts only the temperature conditions are valid).
Continuous cycle
Press
UP
and
DOWN
together for more than 3 sec.
Access and setting type F (frequent) and type C (configuration) parameters.
1.
Press
SET
for 3 sec (the display will show “PS”).
2.
• To access the type F and C parameter menu, enter the password “22” using
UP/DOWN
, press
SET
to
confirm.
• To access the F parameter menu only, press
SET
(without entering the password).
3. Scroll inside the parameter menu using
UP/DOWN.
Summary of Contents for RE-CN-0045-HC
Page 16: ...16 Parts Breakdown Model RE CN 0045 HC 50032...
Page 18: ...18 Parts Breakdown Model RE CN 0009 HC 50033...
Page 20: ...20 Parts Breakdown Model RE CN 0014 H 50035...
Page 22: ...22 Parts Breakdown Model RE CN 0023 HC 50036 Model RE CN 0023 H 50037...
Page 24: ...24 Parts Breakdown Model RE CN 0052 HC 50052...
Page 26: ...26 Parts Breakdown Model FR CN 0012 HC 50029...
Page 28: ...28 Parts Breakdown Model FR CN 0790 HC 50030...
Page 30: ...30 Parts Breakdown Model FR CN 1250 HC 50031...
Page 32: ...32 Parts Breakdown Model FR CN 0045 HC 50075...
Page 34: ...34 Electrical Schematics Model RE CN 0045 HC 50032 Model RE CN 0009 HC 50033...
Page 36: ...36 Electrical Schematics Model RE CN 0052 HC 50052 Model FR CN 0012 HC 50029...
Page 37: ...37 Electrical Schematics Model FR CN 1250 HC 50031 Model FR CN 0790 HC 50030...
Page 38: ...38 Electrical Schematics Model FR CN 0045 HC 50075...