8
Maintenance
ROUTINE INSPECTION
After 200 hours or 30 days of use, inset NON-TOXIC HORRAL-300 white synthetic grease through the right
and left grease inlet pin using a grease gun. To have access to the left grease inlet pin, remove the left side by
unscrewing the screws with a 7/16” service key. The right grease inlet is readily accessible.
WARNING
Always disconnect the machine from the power source before cleaning. Always make sure the mixing tools
are completely stopped before opening the cover. It is recommended that the machine be carefully cleaning
before it is first used, after use, several times a day if it is very dirty and after long periods during which it has
remained off. Clean the machine with rags and sponges. Wipe dry. Only use soaps and detergents suitable for
kitchenware.
CAUTION
The machine cannot be cleaned with water jets. DO NOT clean it with steam jets or high pressure jets or
similar methods as this may result in short circuiting or serious damage to the machine.
REFERENCE
Item Number Model Number
Description
Manufacturer Model Number
13153
MM-BR-0050
Meat Mixer 110 LB / 50 KG
0.5 HP / 373 W 110V/60/1
MMS501