6
Installation
Operation
The MM-BR-0050 must be installed on a flat, non-skid surface. Check the voltage of the machine. The unit
voltage must be the same as the power source voltage. The machine must be properly grounded. Trained
personnel must install the unit according to building codes. Contact Omcan if you have any questions of
problems with the installation or operation of this machine at 1-800-465-0324.
CAUTION
Under no circumstances put hands or any other tool into the meat tank during operation.
Put the product to be processed into the meat tank and lower the cover. Then start the machine by turning the
switch to the “ON” position.
CAUTION: Always load the machine with the motor turned OFF.
DISCHARGING THE PROCESSED PRODUCT
Turn the machine OFF and wait for the mixing tools to be completely stopped. Hold the handle (Pic. 2, #2) that
is fixed on the right side of the meat tank (Pic. 2, #1) and pull out the locking knob (Pic. 2, #3) to release the
meat tank. Open the cover and turn the meat tank to the front of the machine until it gets locked by the locking
knob in the tilting position. Turn the machine ON and OFF as many times as needed to help discharge all the
processed meat from the meat tank. To place the meat tank in the upright position, release the meat tank again
and turn it up, holding the handle.
Technical Specifications
Model
MM-BR-0050
Power
0.5 HP / 0.37 kW
RPM
50
Bowl Capacity
110 lbs. / 50 kgs.
Weight
200 lbs. / 90.7 kgs.
Dimension (DWH)
37” x 16.5” x 39.3” / 940 x 420 x 1092mm
Item Number
13153