11
Maintenance
below.
•
There is a water conduit at the bottom of the freezer, when defrosting, extract the rubber cover, the
defrosted water will drip into the hole and flow out.
NOTE: PLEASE KEEP THE RUBBER COVER SAFE DURING THE DEFROSTING AND PUT IT BACK
AFTER THE DEFROSTING IS COMPLETE.
Troubleshooting
Problem
Cause
Solution
The indicator is not on. The
compressor doses not start.
The plug isn’t connected to the
socket really.
Replug it.
No power.
Connect the socket with power.
The indicator is on, but the
compressor doesn’t work and
buzzes only.
The power voltage is <98V.
Put a power-regulator more than
1000W power together.
The compressor stops a minute
after start, and restart after a few
minutes, and so repeatedly.
The power voltage is >132V.
Put a power-regulator more than
1000W power together.
The compressor works normally,
but the temperature in the cabinet
lowers too slowly.
The door is opened too frequently.
Reduce open times.
The food in the cabinet is too
much, and placed improperly.
Place foods properly keep place
between them for ventilation of
cold air.
The frost film is too thick.
Take out foods and defrost.
The surface of the condenser is
too dirty.
Stop and clean the condenser.
The door seals badly.
Adjust the door seal.
The noise is too loud.
The freezer is placed unstably.
Place it stably.
The fixing of the freezer is loose.
Tighten the fixing.
There’s contact between pipes.
Separate them.
The following are not faults:
•
When the freezer is working or after stopping for a while, the refrigerant in the pipes is cycling and gives out