background image

Gas Fryer

Model CE-CN-0025-CTN

Item 47749

Instruction Manual

Revised - 08/10/2023

Toll Free: 1-800-465-0234

Fax: 905-607-0234

Email: [email protected]

www.omcan.com

Summary of Contents for CE-CN-0025-CTN

Page 1: ...Gas Fryer Model CE CN 0025 CTN Item 47749 Instruction Manual Revised 08 10 2023 Toll Free 1 800 465 0234 Fax 905 607 0234 Email service omcan com www omcan com ...

Page 2: ...8 10 10 12 12 13 14 15 Table of Contents Section General Information Safety and Warranty Technical Specifications Installation Operation Maintenance Troubleshooting Parts Breakdown Warranty Registration Model CE CN 0025 CTN ...

Page 3: ...utmost importance to save these instructions for future reference Also save the original box and packaging for shipping the equipment if servicing or returning of the machine is required Omcan Fabrication et distribution Companie Limité et Food Machinery d Amerique dba Omcan et Omcan Inc ne sont pas responsables de tout dommage ou blessure causé du fait que toute personne ait utilisé cet équipemen...

Page 4: ...l carton para asegurararse que todos los articulos solicitados ésten dentro de la caja y no encuentre daños ocultos en la máquina Si el paquete ha sufrido un manejo de poco cuidado golpes o daños visible o oculto por favor anote en la factura antes de aceptar la entrega y contacte Omcan dentro de las 24 horas de modo que podamos iniciar una reclamación con la compañia Un informe detallado sobre lo...

Page 5: ...ulting from installation in non commercial or residential applications The right is reserved to deny shipment for residential usage if this occurs you will be notified as soon as possible 1 YEAR PARTS AND LABOUR WARRANTY Within the warranty period contact Omcan Inc at 1 800 465 0234 to schedule an Omcan authorized service technician to repair the equipment locally Unauthorized maintenance will voi...

Page 6: ...e in the space provided below This information can be found on the fryer data plate Minimum clearance from noncombustible construction 0 from the sides of the fryer 0 from the back of the fryer Location Install fryer in an area with sufficient air supply for gas combustion at fryer burners Do not obstruct the flow of combustion and ventilation air Provide adequate clearance for air openings into t...

Page 7: ... 75 mm for batteries If using the optional quick disconnect flex hose 19 mm iron pipe for single units and 1 1 4 31 75 cm iron pipe for batteries Make sure the pipes are clean and free of obstructions dirt and piping compound A battery requires one or two connections of appropriate size for the gas requirement Warning prior to lighting check all joints in the gas supply line for leaks Use soap and...

Page 8: ... or sulfate sulfide cleaners Wash any accessories shipped with unit Rinse fryer and accessories thoroughly and drain the fryer Wipe tank completely dry with a soft clean cloth FILLING TANK WITH SHORTENING Solid shortening should NOT be used with this type of fryer Melting solid shortening will damage the tank Close the drain valve Fill the fryer tank with liquid shortening Shortening level should ...

Page 9: ...n pilot 3 To shut off all gas to the system including the pilot turn the gas valve knob to OFF EXTENDED SHUTDOWN 1 Turn the thermostat knob to OFF 2 Push in the pilot knob and turn to OFF 3 Thoroughly drain the fryer Refer to DRAINING THE FRYER 4 Clean the fryer according to CLEANING 5 Turn off the main gas shutoff valve BASIC FRYING INSTRUCTION Set the desired temperature and allow shortening to ...

Page 10: ...t is only on for a few minutes If necessary use the clean out rod to carefully stir the hard shortening to an area above the cold zone where it will melt Use the tank brush to help clear sides and tubes of debris Fry Basket Guidelines Do not overfill baskets Carefully lower basket into oil When frying doughnuts and fritters turn product only once during frying When cooking french fries or onion ri...

Page 11: ...allic scoring pad or harsh cleaners BOIL OUT PROCEDURE Weekly or as required 1 Drain the tank as described under DRAINING THE TANK 2 Once the shortening has been drained flush out scraps and sediment with a small amount of warm shortening using tank brush Allow the tank to drain thoroughly 3 Close the drain valve and fill tank with non corrosive grease dissolving commercial cleaner Follow the manu...

Page 12: ...ature High limit tripped call service Temperature probe call service Tank will not drain Shortening too cold Drain pipe clogged with debris Maintenance MAINTENANCE Warning Hot oil and hot parts can cause burns Use care when operating cleaning and servicing the fryer Warning Spilling hot fryer compound can cause severe burns Do not move fryer without draining all frying compound from the tank FLUE ...

Page 13: ...13 Parts Breakdown Model CE CN 0025 CTN 47749 ...

Page 14: ...749 6 AN724 Burner for 47749 19 AN735 Basket for 47749 32 AN713 Nozzle Base for 47749 7 AD713 Oil Drain Extension Pipe for 47749 20 AN736 1 2 to 3 4 Adaptor for 47749 33 AN714 Nozzle for 47749 8 AD733 Drain Valve for 47749 21 AN737 Gas Pipe for 47749 34 AJ605 Test Plug for 47749 9 AN725 Thermostat for 47749 22 AN738 Back Board for 47749 35 AN715 Union Connector for 47749 10 AN726 Magnet for 47749 ...

Page 15: ...gister online by visiting OMCAN PRODUCT WARRANTY REGISTRATION 3115 Pepper Mill Court Mississauga Ontario Canada L5L 4X5 https omcan com warranty registration or email to service omcan com Purchaser s Information Name Company Name Address Telephone City Province or State Postal or Zip Email Address Country Type of Company Restaurant Bakery Deli Dealer from which Purchased Butcher Supermarket Catere...

Page 16: ...s relations avec nos clients et les fabricants de valeur Aujourd hui avec des partenaires en Amérique du Nord Europe Asie et Amérique du Sud nous travaillons continuellement à améliorer et développer l entreprise Nous nous efforçons d offrir à nos clients une valeur exceptionnelle grâce à nos ventes locales qualifiées et des représentants de service qui offrent un accès facile à plus de 6500 produ...

Reviews: