14
Installation
Operation
STEP 11
1. When working with gas burning, please take out 52”, when working with wood burning, please put in 52”,
completely cover the burner, pay attention to the direction of placement.
LEAK TESTING
GENERAL
Although all gas connections on the grill are leak tested at the factory prior to shipment, a complete gas
tightness check must be performed at the installation site due to possible mishandling in shipment, or
excessive pressure unknowingly being applied to the unit. Periodically check the whole system for leaks
following the procedures listed below. If the smell of gas is detected at any time you should immediately check
the entire system for leaks.
BEFORE TESTING
Make sure that all packaging material is removed from the grill including the burner tie-down straps. DO NOT
SMOKE WHILE LEAK TESTING. NEVER PERFORM LEAK TEST WITH AN OPEN FLAME.
Make a soap
solution of one part liquid detergent and one part water. You will need a spray bottle, brush, or rag to apply the
solution to the fittings. For the initial leak test, make sure the LP cylinder is full.
TO TEST
1. Make sure the control valves are in the “OFF” position, and turn on the gas supply.
2.
Check all connections from the LP gas regulator and supply valve up to and including the connection to