background image

Since 1951 Omcan has grown to become a leading distributor of equipment and supplies to the North 

American food service industry. Our success over these many years can be attributed to our commitment 

to strengthen and develop new and existing relationships with our valued customers and manufacturers. 

Today with partners in North America, Europe, Asia and South America, we continually work to improve 

and grow the company. We strive to offer customers exceptional value through our qualified local sales 

and service representatives who provide convenient access to over 6,500 globally sourced products.

Depuis 1951 Omcan a grandi pour devenir un des “leaders” de la distribution des équipements et 

matériel pour l’industrie des services alimentaires en Amérique du Nord. Notre succès au cours de ces 

nombreuses années peut être attribué à notre engagement à renforcer et à développer de nouvelles 

et existantes relations avec nos clients et les fabricants de valeur. Aujourd’hui avec des partenaires en 

Amérique du Nord, Europe, Asie et Amérique du Sud, nous travaillons continuellement à améliorer et 

développer l’entreprise. Nous nous efforçons d’offrir à nos clients une valeur exceptionnelle grâce à 

nos ventes locales qualifiées et des représentants de service qui offrent un accès facile à plus de 6500 

produits provenant du monde entier.

Desde 1951 Omcan ha crecido hasta convertirse en un líder en la distribución de equipos y suministros 

de alimentos en América del Norte industria de servicios. Nuestro éxito en estos años se puede atribuir 

a nuestro compromiso de fortalecer y desarrollar nuevas relaciones existentes con nuestros valiosos 

clientes y fabricantes. Hoy con socios de América del Norte, Europa, Asia y América del Sur, que trabajan 

continuamente para mejorar y crecer la empresa. Nos esforzamos por ofrecer a nuestros clientes valor 

excepcional a través de nuestro local de ventas y representantes de los servicios que proporcionan un 

fácil acceso a más de 6,500 productos con origen a nivel mundial.

Summary of Contents for 47351

Page 1: ...Gas Wok Range Model CE CN WOK NG Item 47351 Instruction Manual Revised 12 09 2021 Toll Free 1 800 465 0234 Fax 905 607 0234 Email service omcan com www omcan com ...

Page 2: ...9 10 10 11 12 13 14 15 Table of Contents Section General Information Safety and Warranty Technical Specifications Installation Operation Maintenance Troubleshooting Parts Breakdown Notes Warranty Registration Model CE CN WOK NG ...

Page 3: ...utmost importance to save these instructions for future reference Also save the original box and packaging for shipping the equipment if servicing or returning of the machine is required Omcan Fabrication et distribution Companie Limité et Food Machinery d Amerique dba Omcan et Omcan Inc ne sont pas responsables de tout dommage ou blessure causé du fait que toute personne ait utilisé cet équipemen...

Page 4: ...ararse que todos los articulos solicitados ésten dentro de la caja y no encuentre daños ocultos en la máquina Si el paquete ha sufrido un manejo de poco cuidado golpes o daños visible o oculto por favor anote en la factura antes de aceptar la entrega y contacte Omcan dentro de las 24 horas de modo que podamos iniciar una reclamación con la compañia Un informe detallado sobre los daños causados a l...

Page 5: ...ponent failure or other damages resulting from installation in non commercial or residential applications The right is reserved to deny shipment for residential usage if this occurs you will be notified as soon as possible 1 YEAR PARTS AND LABOUR BENCH WARRANTY Within the warranty period contact Omcan Inc at 1 800 465 0234 to schedule a drop off to either an Omcan authorized service depot in the a...

Page 6: ...ith written or electronic communication 3 All original packing materials must be kept for inspection purposes 4 The Wok range can t have been moved installed or modified Remove all packing material and protective plastic from the surfaces of the unit Before installing verify that the type of gas natural or propane and the clearance dimensions agree with the specifications on the rating plate which...

Page 7: ...resistive to natural gas This range uses NG56 connections for gas nozzles MANUAL SHUT OFF VALVE This installer supplied valve must be in the gas service line ahead of the appliance regulator in the gas stream and in a position accessible in the event of an emergency CONNECTIONS Please check installer supplied intake pipes visually and or blow them with compressed air to clear any dirt particles th...

Page 8: ...he appliance must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 or the Canadian Electrical Code CSA C22 2 as applicable A manual gas shut off valve must be installed in the gas supply line ahead of the appliance and gas pressure regulator for safety and ease in servicing The gas pressure regulator supplied mu...

Page 9: ...me failure device will shut the gas off If you notice the flame was extinguished please turn the flame control valve to OFF position and re ignite the pilot flame A 5 minutes complete shut off period should be allowed before the appliance is relighted SHUTTING DOWN Turn the flame control valve backwards to the OFF position to extinguish the burner If the gas appliance will not be used for a prolon...

Page 10: ... impossible to remove Ensure your wok range is checked by a qualified technician once a year for efficient operation of the appliance CONTACT THE APPLIANCE SUPPLIER OR A LOCAL SERVICE COMPANY TO PERFORM ALL MAINTENANCE AND SERVICE REPAIRS PROBLEM POSSIBLE CAUSES SOLUTIONS Pilot not lighting Insufficient gas pressure in pipe Contact local gas supply department Nozzle occlusion Dredge nozzle Pilot i...

Page 11: ...requirements Adjust nozzle diameter Not enough air to ignite Increase damper opening degree Gas spikes and floats Turn down valve flow THE PROBLEMS MENTIONED ABOVE ARE FOR REFERENCE ONLY IF ANY FAULT OCCURS STOP USING THE MACHINE IMMEDIATELY AND CONTACT AN AUTHORIZED TECHNICIAN TO CHECK AND MAKE REPAIRS ...

Page 12: ...12 Parts Breakdown Model CE CN WOK NG 47351 ...

Page 13: ...3 AI578 Support Beam for 47351 11 AI586 Duck Mouth Burner for 47351 20 AI571 Side Plate Left and Right for 47351 4 AI579 Input Pipe Mount Pad for 47351 12 AI587 Union for 47351 21 AI572 Tray Guide for 47351 5 AI580 Support Leg for 47351 13 AI588 Street Elbow for 47351 22 AI573 Tray for 47351 6 AI581 Regulator for 47351 14 AI589 Pilot Head with Tube for 47351 23 AI574 Bottom Plate for 47351 7 AI582...

Page 14: ...________________ ________________________________________________________________________________________ ________________________________________________________________________________________ ________________________________________________________________________________________ ________________________________________________________________________________________ ___________________________...

Page 15: ...gister online by visiting OMCAN PRODUCT WARRANTY REGISTRATION 3115 Pepper Mill Court Mississauga Ontario Canada L5L 4X5 https omcan com warranty registration or email to service omcan com Purchaser s Information Name Company Name Address Telephone City Province or State Postal or Zip Email Address Country Type of Company Restaurant Bakery Deli Dealer from which Purchased Butcher Supermarket Catere...

Page 16: ...s relations avec nos clients et les fabricants de valeur Aujourd hui avec des partenaires en Amérique du Nord Europe Asie et Amérique du Sud nous travaillons continuellement à améliorer et développer l entreprise Nous nous efforçons d offrir à nos clients une valeur exceptionnelle grâce à nos ventes locales qualifiées et des représentants de service qui offrent un accès facile à plus de 6500 produ...

Reviews: