background image

6

Installation

precautions.

•  You must fill the vacuum pump with NO.68 or NO.100 vacuum pump oil before use. When running, the oil 

level should not be lower than 1/3 height of oil window. Do not fill beyond the 1/2 mark.

• 

The machine should be placed horizontally in good ventilation without corrosive gas and heavy dust.

•  The power connection position may be located on a different side, so be sure to do grounding protection 

before use.

• 

Always ensure the top cover is open before turning the power on. Start the machine by pressing the top 

cover and the process will start automatically.

•  Preheating of vacuum pump must be done in a low temperature working area. Turn off the heater selection 

switch at the control panel to off position. This is to prevent heating process and to cut down wear and tear 

of the unit. Run the vacuum pump a few time and machine will be ready to use.

SETTINGS

Please set every parameter first before starting the machine.

• 

Turn on the power supply, check through the settings on the panel and make sure “------” must be shown 

after setting is done. Otherwise, operation of this machine will not work if the setting is not on this mode.

• 

Press the setting button, the indicator lamp of the unit will light to enter into the setting state of vacuum 

timing. Press the upward or downward key to increase or decrease vacuum time in the range of 0-99 

seconds.

• 

Press the parameter set key, the heating indicator lamp lights up to enter into the heating setting state. 

Press the upward or downward key to increase or decrease the heating sealing time in the range of 0-3.5 

seconds.

• 

After the heating time is set, press the set key again, the cooling indicator lamp lights up to enter into the 

setting state of cooling time in the range of 0-9.9 seconds.

•  After the cooling time is set, press the set key again to finish the parameter setting, and “Ed” is shown in 

the panel.

• 

Press the “temperature selection” set key to enter into temperature set state. Press the set key once, 

indicate one corresponding temperature value, and the lamp shows an orange color; there are three 

selections such as “high temperature”, “middle temperature” and “low temperature”.

REMARKS & TIPS

Ways to quickly process a small item or product using a bigger chamber is to place a solid block into the 

chamber as to allow less vacuum time needed due to compact space.

IMPORTANT: DO NOT BLOCK THE AIR HOLE IN THE CHAMBER

Summary of Contents for 43632

Page 1: ...Vacuum Packaging Machine Model VP CN 0600 Item 43632 Instruction Manual Revised 06 16 2022 Toll Free 1 800 465 0234 Fax 905 607 0234 Email service omcan com www omcan com...

Page 2: ...12 12 13 14 15 Table of Contents Section General Information Safety and Warranty Technical Specifications Installation Operation Maintenance Troubleshooting Parts Breakdown Electrical Schematics Warra...

Page 3: ...e It s of the utmost importance to save these instructions for future reference Also save the original box and packaging for shipping the equipment if servicing or returning of the machine is required...

Page 4: ...uncionamiento de esta m quina y sta usando ropa apropiada y autorizada Cualquier modificaci n a la m quina an la la garant a y puede causar da os a las personas usando la m quina mientras esta en el f...

Page 5: ...g we suggest disposing of the products separately differentiated waste according to the current norms DO NOT DISCARD ANY PACKAGING MATERIALS IN THE ENVIRONMENT Technical Specifications Model VP CN 060...

Page 6: ...machine will not work if the setting is not on this mode Press the setting button the indicator lamp of the unit will light to enter into the setting state of vacuum timing Press the upward or downwar...

Page 7: ...rse timing of heating It will enter into cooling state automatically after the timing is finished According to the time setting the machine doesn t act when cooling the panel shows till the reverse ti...

Page 8: ...200 working hours If packing wet product it is recommended to change the oil every 150 working hours REPLACING THE SEALING TAPE AND HEATING WIRE 1 Disconnect the cable from the pin then pick the comp...

Page 9: ...y then remove the heating wire 5 Put one side of a new heating wire into the fastener groove and tighten it with the Allen Key 6 Put the other side of the heating wire into the other side fastener gro...

Page 10: ...aining sealing tape on the ends to allow them to fold over 10 Put plastic clamps on the sides of the sealing bar 11 Install the stainless steel base and pressing stick 12 Connect the cable of the comp...

Page 11: ...in bag after processing is finished the possible reasons are as follows Wrong position resting on sealing bar Redo it Uneven sealing pressure bar presses the bag opening side so that air cannot escap...

Page 12: ...No Description Position Item No Description Position AC294 Working Transformer for 43632 1 AC300 Vacuum Pump for 43632 7 AC306 Assemble Sealing Bar for 43632 13 AC295 Sealing Transformer for 43632 2...

Page 13: ...13 Parts Breakdown Model VP CN 0600 43632...

Page 14: ...14 Electrical Schematics Model VP CN 0600 43632...

Page 15: ...ter online by visiting OMCAN PRODUCT WARRANTY REGISTRATION 3115 Pepper Mill Court Mississauga Ontario Canada L5L 4X5 https omcan com warranty registration or email to service omcan com Purchaser s Inf...

Page 16: ...relations avec nos clients et les fabricants de valeur Aujourd hui avec des partenaires en Am rique du Nord Europe Asie et Am rique du Sud nous travaillons continuellement am liorer et d velopper l e...

Reviews: