Troubleshooting

VACUUM PUMP AND VACUUM SYSTEM

Vacuum pump does not start, the possible reasons are as follows:

•  Limit switch is not pressed on:

 

- Close the machine cover and adjust the limit switch. 

- Adjust the pull-rod for electric cover opening machine.

• 

Time relay of vacuum pump is damaged: 

- Replace it.

• 

Dynamo of vacuum pump is damaged: 

- Replace it.

Vacuum chamber cannot reach the vacuum degree, the possible reasons are as follows:

• 

Vacuum degree cannot be reached because vacuum pump is worn or damaged.

•  Loose air pipe joint, broken pipe, damaged sealing ring of vacuum chamber or damaged solenoid valve 

causes the entry of air into vacuum chamber.

•  Insufficient oil in vacuum pump.

• 

Vacuum timing is not enough.

Vacuum chamber cannot be opened, the possible reasons are as follows:

• 

Air-bleed solenoid valve is not turned on.

• 

For electric cover opening machine, the cover opening motor may be damaged, or pull rod is jammed.

Air remains in bag after processing is finished, the possible reasons are as follows:

• 

Wrong position resting on sealing bar. 

- Redo it.

• 

Uneven sealing pressure bar presses the bag opening side so that air cannot escape.

Abnormal sound or tripping when running, black smoke or oil drop at air vent:

• 

Abnormal sound of fan of pump motor, it should be repaired.

• 

Blockage may be seen in air intake and/or pipe.

•  Insufficient oil of vacuum pump or the use of non-standard lubricant.

•  Long-time running of pump or overheat running under high temperature, please keep the machine 

ventilated and heat radiated.

• 

Faulty vacuum pump motor or solenoid valve of vacuum pump or wear and tear due to usage.

• 

Replace parts or contact the manufacture factory.

HEAT SEALER

Incapable sealing, the possible reasons are as follows:

• 

The heating sealing selector switch is not selected and the heating power is not turned on.

•  The heating element is damaged and the power connecting position of heating element is cut off.

• 

The heating time is set at “0”.

• 

The heating time relay is damaged.

•  The sealing solenoid valve does not act and gas bag does not bulge (or gas bag is damaged).

Summary of Contents for 43632

Page 1: ...Vacuum Packaging Machine Model VP CN 0600 Item 43632 Instruction Manual Revised 06 16 2022 Toll Free 1 800 465 0234 Fax 905 607 0234 Email service omcan com www omcan com...

Page 2: ...12 12 13 14 15 Table of Contents Section General Information Safety and Warranty Technical Specifications Installation Operation Maintenance Troubleshooting Parts Breakdown Electrical Schematics Warra...

Page 3: ...e It s of the utmost importance to save these instructions for future reference Also save the original box and packaging for shipping the equipment if servicing or returning of the machine is required...

Page 4: ...uncionamiento de esta m quina y sta usando ropa apropiada y autorizada Cualquier modificaci n a la m quina an la la garant a y puede causar da os a las personas usando la m quina mientras esta en el f...

Page 5: ...g we suggest disposing of the products separately differentiated waste according to the current norms DO NOT DISCARD ANY PACKAGING MATERIALS IN THE ENVIRONMENT Technical Specifications Model VP CN 060...

Page 6: ...machine will not work if the setting is not on this mode Press the setting button the indicator lamp of the unit will light to enter into the setting state of vacuum timing Press the upward or downwar...

Page 7: ...rse timing of heating It will enter into cooling state automatically after the timing is finished According to the time setting the machine doesn t act when cooling the panel shows till the reverse ti...

Page 8: ...200 working hours If packing wet product it is recommended to change the oil every 150 working hours REPLACING THE SEALING TAPE AND HEATING WIRE 1 Disconnect the cable from the pin then pick the comp...

Page 9: ...y then remove the heating wire 5 Put one side of a new heating wire into the fastener groove and tighten it with the Allen Key 6 Put the other side of the heating wire into the other side fastener gro...

Page 10: ...aining sealing tape on the ends to allow them to fold over 10 Put plastic clamps on the sides of the sealing bar 11 Install the stainless steel base and pressing stick 12 Connect the cable of the comp...

Page 11: ...in bag after processing is finished the possible reasons are as follows Wrong position resting on sealing bar Redo it Uneven sealing pressure bar presses the bag opening side so that air cannot escap...

Page 12: ...No Description Position Item No Description Position AC294 Working Transformer for 43632 1 AC300 Vacuum Pump for 43632 7 AC306 Assemble Sealing Bar for 43632 13 AC295 Sealing Transformer for 43632 2...

Page 13: ...13 Parts Breakdown Model VP CN 0600 43632...

Page 14: ...14 Electrical Schematics Model VP CN 0600 43632...

Page 15: ...ter online by visiting OMCAN PRODUCT WARRANTY REGISTRATION 3115 Pepper Mill Court Mississauga Ontario Canada L5L 4X5 https omcan com warranty registration or email to service omcan com Purchaser s Inf...

Page 16: ...relations avec nos clients et les fabricants de valeur Aujourd hui avec des partenaires en Am rique du Nord Europe Asie et Am rique du Sud nous travaillons continuellement am liorer et d velopper l e...

Reviews: