FM TRANSMITTER
TR
EM
1000
HE
DIG
PLUS
COMPACT
Technical Manual 1v2 November 2019
45
- FREQUENCY setting
It is used to define the transmitter’s operating frequency.
The following parameters can be set:
•
Step
– frequency increments can be selected (in the example, 100 KHz)
•
Frequency
– operating frequency
- POWER setting
It is used to adjust the transmitter’s output power.
The display shows the following:
•
Pow. set
– set power
•
Pow. out
– measurement of the power supplied
- MPX SENS setting
It is used to adjust modulation input sensitivity according to the low frequency level available.