FM TRANSMITTER
TR
EM
1000
HE
DIG
PLUS
COMPACT
Technical Manual 1v2 November 2019
28
21) Ensure that the
EDIT
option is selected; otherwise, turn the knob to select it, then press to
confirm.
22) A value will be indicated after
Nom. Input
, normally pre-defined at
+0.0dBm
.
23) Turn the knob to adjust the value based on the modulation level used. The peak deviation
indicated by
Mpx
, expressed in KHz, will consequently be changed. Note that, to the right of
the deviation, the value of the modulating signal will be indicated, as compared to the
nominal value set.
24) Ensure that the measured peak deviation does not exceed local regulations, then press
the knob to confirm the setting.
25)
OK
will be highlighted. Three choices are now available:
- If the parameters set are correct – skip directly to step 26) to confirm the settings.
- If the parameters set are all incorrect – cancel all settings by turning the knob until
ABORT
is
highlighted, then skip to step 26).
- If a slight adjustment to the parameters is required – turn the knob until
EDIT
is highlighted,
then return to step 22).
26) Press the knob to confirm. You will return to the page indicated in step 3).
2.2.5 Modulation limiter
27) Turn the knob until the
LIMITER
sub-menu is selected, then press the knob to confirm.
28) The modulation limiter adjustment screen will appear: