TO REACH THE PARAMETERS MENU
-
First of all, make sure that the thermostat is not in any operation, is not in standby
mode and the key lock is released.
-
Press and hold the SET button for 10 seconds. ATTENTION! At first press and
hold for 4 seconds Anand will stand-by mode. Keep printing. Do not take your
hand. “PA” will appear on the display.
-
- Press the SET button once and remove your hand.
-
- Enter the parameter password using the up and down arrow keys for 15 seconds.
(This value is determined by the “PAS” parameter in the user parameters. The
factory setting is “-19”. If the relevant parameter is set to “0”, the parameters can
be accessed without a password. If the password has been changed, consult your
sales representative.)
-
Quickly press the SET button and remove your hand or wait for 15 seconds
without any action.
“SP” will appear on the screen. (If the password has been
canceled, “SP” will appear directly on the screen after the first operation.
-
Chose the parameter you want and press the SET button.
-
- Use the down and arrow keys to set the value you want within 15 seconds.
-
- Press the SET button once and remove your hand.
-
- Press and hold the SET button for 4 seconds or wait for 60 seconds without any
operation.
PARAM.
MINIMUM
MAXIMUM
UNIT
FACTORY
SETTINGS
SET VALUE
SP
r1
r2
°C / °F
0
Setting the value of the operating
temperature
PARAM.
MINIMUM
MAXIMUM
UNIT
FACTORY
SETTINGS
MEASUREMENT AND
SENSORS
O1
-99
99
°C / °F
0
Cabinet sensor calibration
P2
0
1
----
0
Selecting the unit of measurement
0 = Celsius 1 = Fahrenheit
P8
1
10
----
0
Selecting the unit of measurement
0 = Fastest 1 = Slowest
PARAM.
MINIMUM
MAXIMUM
UNIT
FACTORY
SETTINGS
WORKING CYCLE
r0
-99
99
°C / °F
2
Working setpoint differential
(If the value is negative, it works
symmetrically, if it is positive, it
works asymmetrically.
r1
-99
r2
°C / °F
-40
(If it is desired to assign limits to
adjust the setpoint) lower setpoint
limit
r2
r1
99
°C / °F
50
(If it is desired to assign limits to
adjust the setpoint) the upper limit
of the setpoint
PARAM.
MINIMUM
MAXIMUM
UNIT
FACTORY
SETTINGS
COMPRESSOR
PROTECTION