3.2 DESCRIPTION
3.2.1 INTERFACE
Fig. 1_INTERFACE OF EQ-C-S
(The aspect may slightly change between daws).
3.2.2 FUNCTIONS
1. “O” button is provided to reset all Eqs, Phases and
the Master to zero, it can be used as a bypass
with the use of the undo button “<” (For a true
bypass use the DAW bypass button);
2. Options, on Standalone plugin only, this is the
audio settings, input and output & the buffer size
settings, it requires to restart the app after a
change;
3. File name input to specify for the correction-1.txt &
correction-2.txt files to import or to export as
“correction”;
4. The “R” button is used to read/import the values
from the previously specified file name ;
5. The “S” button is used to Save the EQ’s sliders
settings in a filename-1.txt & filename-2.txt files;
6. The “<“ button is an undo button, which permits to
recover the previous EQ’s settings after a change;
7. The “>” button is a redo button, the undo and redo
button can be used to compare different settings;
8. The combo box lists the Window's functions to be
selected;
9. The “Factors” slider is a global “FIR factor” setting,
relatively to the selected window function, it acts
as an all EQs slope setting;
10. The “S.Rate" or Sample Rate indicator.
11. The “Coeffs" indicates the maximum number of
coefficients in use per filter;
12. EQ for the left and right channel, in mono or mono
to stereo configurations;
13. dB Indicators are provided on the right and left of
the EQs for the sliders;
14. LF is for the lower frequencies range, HF for the
higher frequencies range, all others are Band-pass
filters:
15. The LVL slider provided for each channel can also
be used as a balance control and also, it
automatically limits the sound level when
correction-x.txt are imported;
16. There are direct numerical value indicators and
also input editors for the filters, the Factors, and
the Master sliders;
17. The “MST” slider acts as a global output level in
stereo.
18. The button L for “Link”, permits to link the control
of the right channel to left channel.
19. The buttons EQ & PH will display the Eqs or the
Phases corrections sliders.
20. The button A for Auto Level, will set the outputs
peak levels corresponding to the inputs levels,
also the level indicator which only take
measurements of the left channel, while clipping
will show the maximum measured peak, and by
clicking on it, it will reduce the level by this value
and - 3dB, reseting also its original state and the
memorized values for the Auto Levels button “A”.
21. It was also added a bypass button “B” which is a
true bypass of the equalizer itself.
22. Also, the “I” button was added to help invert the
EQ's levels or the Phases Deviations.
3.2.3 KEYBOARD SHORTCUTS
✔
Holding the ctrl keyboard key and grabbing a
slider to change its values with more precision;
✔
By holding the alt keyboard key and clicking on a
slider knob, the slider goes to its initial value, it
could also be done by double clicking the slider
knob.
3
Summary of Contents for EQ-C
Page 1: ......