4 - The pump should be installed near the source, from which it sucks.
5 - Reduce at min. bends and necks along the whole line.
6 - Use large radius bends, avoiding Tees and needless runs.
7 - Check the perfect inlet connection seal not to reduce the pump suction power.
8 - The piping weight must not load on pump body and the
connection must be carried out without forcing in order to
avoid overloads and distortion of the rotor case.
9 - Especially in case of very long piping system isolation
valves on both inlet and outlet side to permit pump
maintenance and removal without total draining of the piping
system.
10 - Where possible arrange a flexible expansion joint to
reduce vibration and to avoid forcing, due to thermal
expansion of piping.
11 - We advise to arrange gauges and vacuum gauges near
the pump. They are usefull to check the pump working
conditions and diagnose possible trouble such as:
– pressure overload
– flow absence
– instability in duty conditions
– cavitation
12 - Where necessary arrange on inlet a filter, whose suction area must not be smaller than 4-5 time the suction pipe
to minimize the friction losses.
13 - During the pump unit installation it's necessary to leave a usefull room for maintenance and possible removal.
14 - If the pump is not flooded, arrange on inlet side a "foot" valve or a check valve to keep the priming.
6
Fig. 5
Fig. 4
Fig. 3
Fig. 2
Summary of Contents for B Series
Page 1: ...Installation operation and maintenance manual AUT N 810 EDIZ 07 01 ...
Page 36: ...36 Fig 21 Safety valve and hand by pass 3 BY PASS SAFETY VALVE ON PUMP COVER ...
Page 38: ...38 Fig 18 Pump type B105 B110 B115 ...
Page 39: ...39 Fig 19 Pump type B215 B220 B325 B330 B430 B440 ...
Page 40: ...40 Fig 20 Pump type B550 B660 B680 ...
Page 43: ...43 ...
Page 44: ...44 ...
Page 45: ...45 ...
Page 46: ...46 Fig 40 Cross section type B100 ...
Page 47: ...47 Fig 41 Pump type B100 ...
Page 50: ...50 ...
Page 51: ...51 ...