CAUTION
The amplifier must be installed in such a way that free flow of hot air from the tube is
allowed. The amplifier must not be installed in a constrained surrounding (i.e. tight shelves
etc.). During long time operation ventilation grid can reach high temperature. Do not
touch the top cover of the PA in these places during operation.
CAUTION
The amplifier must be properly grounded during operation
.
CAUTION
During operation the amplifier must be installed in such a way that the rear side remains
accessible.
CAUTION
The amplifier is an A category product. In a household it can influence other electric
appliances. In such cases the user is to take proper actions to mitigate this disturbance.
CAUTION
Make sure that all screws holding the case together are properly in place and tightened
before carrying the amplifier with the handles!
CAUTION
Read this manual carefully. Fallow all of instructions during installation and operation to
avoid damage to the amplifier not covered by manufacturer´s warranty! Do not attempt to
perform any change of hardware or software!
3.
GENERAL DESCRIPTION
3.1. HF part
his amplifier is using two pieces of ceramic tetrode FU728F
in a grounded-cathode circuit (input
into control grids). OM4000A amplifier achieves excellent linearity by the voltage
stabilization of the control grid bias and the screen voltage. The power input is given to
the control grids, using a broadband input circuit with an input impedance of 50 Ohms.
This adaptable input circuitry ensures a good input SWR (better
than 1.2:1) on all amateur
bands.
T
Summary of Contents for X8NOM4000A
Page 28: ...Page 28 from 38 7 1 ...
Page 29: ...Page 29 from 38 7 2 Example of connection for ELECRAFT ...
Page 30: ...Page 30 from 38 7 3 Example of connection with Yeasu ...
Page 31: ...Page 31 from 38 7 4 Example of connection with antenna switch and BPF ...
Page 32: ...Page 32 from 38 7 5 Example of connection USB micro KEYER II with IC7800 or IC7700 ...
Page 33: ...Page 33 from 38 7 6 Example of connection USB micro KEYER II with another Icom ...
Page 34: ...Page 34 from 38 7 7 Example for connection USB micro KEYER II with Yeasu or ELECRAFT ...
Page 35: ...Page 35 from 38 7 8 Example of connection PA with MicroHAM MKII MK2R etc with CI V output ...