ANT & BPF SW
- r DB-25 is used for switching of external HP BPF or external Antenna
Switch. Maximum switching of 30V / 0.5A is possible.
PIN OUT:
1.
antenna port 1
2.
antenna port 2
3.
antenna port 3
4.
antenna port 4
5.
antenna port 5
6.
antenna port 6
7.
antenna port 7
8.
antenna port 8
9.
antenna port 9
10.
antenna port 10
11.
COMMON port of ANT SW
12.
NC
13.
GND
14.
BPF 160m
15.
BPF 80m
16.
BPF 40m
17.
BPF 30m
18.
BPF 20m
19.
BPF 17m
20.
BPF 15m
21.
BPF 12m
22.
BPF 10m
23.
COMMON BPF port
24.
NC
25.
GND
Cooling
The centrifugal blowers provide the necessary cooling of the amplifier, even during long contests. The
main blower is activated by switching the PA on and it is turned off when after-cooling is finished
(approx. 1-5 min after switching off the PA depending on the temperature of the tube). The
supplemental fan is turned on depending on the temperature of the air exiting from the amplifier. It is
switched on at 70°C and switched off at 60°C.
Summary of Contents for OM2500 A
Page 1: ...Instruction Manual OM2500 A SHORTWAVE POWER AMPLIFIER OM POWER s r o 930 30 B 126 SLOVAKIA...
Page 12: ...Example of AUTO mode using ICOM TRX Example of AUTO mode using Kenwood TRX...
Page 15: ...Example of connection for Icom...
Page 16: ...Example of connection for ELECRAFT...
Page 17: ...Example of connection with Yeasu...
Page 19: ...Example of connection with antenna switch and BPF...
Page 24: ...Example of connection PA with Microham MKII MK2R etc with CI V output...