5
1.2.3. Indicators
There are few visible LED indicators on the front panel for information on operating
condition, a few buttons and a graphic display.
LED Indicators
STBY - Standby mode
OPERATE - Operation mode
CW - CW mode
PREAMP - Control v12V DC for optional RX
preamplifier switching
FAULT - Failure
ON AIR - Transmit mode
Buttons UP – DWN - Listing in LCD menu
- Scroll trough the alphabet in edit mode
- Changing parameters
OPER - Operation mode
SET - confirms parameters
- Cursor to the right in edit mode
- Settings menu
PRE - Preamplifier ON
- Edit mode start, cursor to the left in edit mode
CW/SSB - mode switch
OSD Indicator 140 x 16 dot graphic display to view:
- Display menu
- Settings menu
- Warning & fault messages
2. SAFETY INSTRUCTIONS
WARNING! Before you will start to install and operate power amplifier, read carefully
next safety instructions!
WARNING! AVOID CHILDREN to play around PA or to touch power amplifier or
connected cables in working condition, or to push anything into the fan holes!
WARNING! Never turn the amplifier on without the upper lid in place.
WARNING! The OM1006 amplifier should not be used in WET or HUMID
environment or exposed to RAINFALL!