EN 8
2. Advance check of the Case
Advance check before use
This Case has been the subject of thorough quality control for the parts during the manufacturing
process and thorough function inspections during the assembly. In addition, a water pressure test is
performed with a water pressure tester for all products to confirm that the performance conforms to the
specifications.
However, depending on the carrying, storage conditions and the maintenance status, etc., the
waterproof function may be damaged.
Before using, always perform the following advance checks.
Advance check
1
Before loading the digital camera in the Case, immerse the empty Case to confirm that there is no
water leakage. When it is difficult, water leakage can be checked by referring “Water leakage
test” (P. 13).
2
Main causes of water leakage are as follows.
• Forgetting to install the O-ring
• Part of an O-ring or an entire O-ring is outside the specified groove.
• O-ring damage, cracks, deterioration or deformation
• Sand, fibers, hair or other foreign matter sticking to the O-ring, the O-ring groove or the O-ring
contact surface.
• Damage to an O-ring groove or O-ring contact surface.
• Attached strap or silica gel getting caught when closing the Case.
Perform the test after the above causes have been eliminated.
CAUTION:
If the advance test should show water leakage with normal handling, stop using the Case and contact your
dealer or an Olympus service station.
PT-EP06_EN.Book Page 8 Monday, September 26, 2011 5:01 PM
Summary of Contents for PT-EP06
Page 1: ...PT EP06 EN Instruction Manual PT EP06_EN Book Page 1 Monday September 26 2011 5 01 PM...
Page 22: ...PT EP06_EN Book Page 21 Monday September 26 2011 5 01 PM...
Page 23: ...PT EP06_EN Book Page 22 Monday September 26 2011 5 01 PM...
Page 24: ...2011 VM144001 PT EP06_EN Book Page 23 Monday September 26 2011 5 01 PM...