![Olympus CKX31 Repair Manual Download Page 25](http://html1.mh-extra.com/html/olympus/ckx31/ckx31_repair-manual_4056632025.webp)
No.
Parts name
Screw
Grease Adhesive
Remark
KNOB
(A)
(B)
(C)
(D)
(E)
ACU3X10SA, 1pc. (*1)
CABLE ASS’Y
CABLE ASS’Y
BOTTOM PLATE
CABLE ASS’Y
(G)
FERRITE CORE
(H)
PLATE
(I)
COVER
CIRCUIT BOARD
(F)
HWB3SA, 1pc. (*3)
CUKS3X8SA, 4pcs. (*4)
HWB3SA, 1pc. (*5)
CTK3X6SA, 4pcs. (*2)
Connection to CN1
(output side connector)
Connection to CN3
(rheostat ass’y connector)
Connection to CN2
(lamp connector)
Voltage adjustment:
it is necessary to adjust it if
the rheostat ass’y or circuit
board (F) is replaced
individually.
(Refer to D-14.)
It is used to fix the cover (I)
to the base of frame.
CUK3X6SA, 4pcs. (*6)
SW3SA, 4pcs. (*7)
CUK3X6SA, 1pc. (*8)
SW3SA, 1pc. (*9)
KNW3SA, 1pc. (*10)
CUKK3X5SA, 2pcs. (*11)
* Be sure to turn off power during disassembly and reassembly.