Designated
haiogen bulbs:
12V100WHAL (PHILIPS 7724)
12V50WHAL-L (LIFE JC)
# The microscope also incorporate a fuse (this should be
replaced by the manufacturer or an authorized agent).
5. When lowering the stage by pressing the stage DOWN button @, be
careful not to have your hand caught between the bottom ² of the con-
denser and the base.
6. The surfaces of the lamp housing on the rear of the microscope will
become extremely hot during operation. When installing the microscope,
make sure to allow ample free space (10 cm or more) around and in
particular above the lamp housing.
7. When installing the microscope, route the power cord away from the
lamp housing. Should the power cord come in contact with the hot lamp
housing, the power cord could melt and cause electric shock.
8. To avoid potential shock hazards and burns when replacing the light
bulb, set the main switch ³ to “ ” (OFF) then disconnect the power cord
from the wall outlet in advance. Whenever you replace the bulb during
use or right after use, allow the lamp housing | and bulb to cool before
touching. (Fig. 2)
Symbol
Explanation
The following symbols are found on the microscope. Study the meaning of the symbols and always use the equip-
ment in the safest possible manner.
Indicates that the surface becomes hot, and should not be touched with bare hands.
Before use, carefully read the instruction manual. Improper use could result in personal injury to
the user and/or damage to the equipment.
Indicates that the main switch is ON.
Indicates that the main switch is OFF.
Warning engraving/stickers are placed at parts where special precaution is required when handling and using the
microscope. Always heed the warnings.
Warning engraving
position
Lamp housing
(Warning against high temperature)
l
Safety Symbols
Warnings
9. Always use the power cord provided by Olympus. If no power cord is
provided, please select the proper power cord by referring to the section
“PROPER SELECTION OF THE POWER SUPPLY CORD” at the end of
this instruction manual. If the proper power cord is not used, product
safety performance cannot be warranted.
Always ensure that the
grounding terminal
of the microscope and that
of the wall outlet are properly connected. If the equipment is not grounded,
Olympus can no longer warrant the electrical safety performance of the
equipment.
Never insert metallic objects into the air vents of the microscope frame
as this could result in electrical shock, personal injury and equipment
damage.
When using the U-FWR motorized filter wheel for reflected light observa-
tion, remove the push ring driver from the position where it is attached by
magnetism in advance to prevent it from dropping.
If the driver drops in a certain place, an electric shock and/or burns may result.
11.
³
|
Fig. 2
Fig. 1
@
²
12.
10.