INSTALLATION INSTRUCTIONS

1. Install the included mounting accessories to hook the 
    device from the mounting holes (fig. 1)

.

2. 

Unfasten the 4 mounting screws to remove the front plastic 

    cover (fig. 1)

.

3. Make sure that the battery’s cables are connected to the 
    respective poles. Black cable to (-) pole and red cable to (+) 
    pole.
4. Install the included  
    cable gland or the 
    rubber o-ring. Pass  
    thru the mains cable  
    and stabilize it by 
    fastening the cable 
    gland. 
    Connect the wires to 
    the terminal blocks 

L

 

    

for live wire and

 

Ν

 

for 

    

neutral

.

5. 

Refit with care the 

    front plastic cover, by 
    fastening the 4
    mounting screws 
    (tightening torque 1Nm).

m i n i m u m   a u t o n o n o u s   d u r a t i o n   b y  
disconnecting  the  mains  power  supply

Count 

the time that  the 
lamps  light  and  in  case  of  less  time  than  the 
minimum  autonomous  duration  the  batteries 
must  be  replaced.  If  the  measured  time  is 
c o n s i d e r a b l y   l e s s   t h a n   t h e   m i n i m u m  
autonomous duration 

 

contact the installer.

The  replacement  of  the  battery  and  the  light 
source  must  be  done  using  parts  of  the  same 
type,  by  the  manufacturer  or  by  a  competent 
person.

5. 

In  case  of  inactive  use  for  a  period  greater 

than  2  months,  disconnect  the  battery  by 
pulling out the battery’s connector.

6. 

I

s not allowed to discard batteries in to 

t i

common  trash  bins,  they  must  be 
discarded  only 

 

in  battery  recycling 

points. Do not incinerate.

 

NOTE: 

LED= Light Emitting Diode    

LABELING EXPLANATION:
X: Self contained   
0: Non-maintained 

(*)

A: Including test device  
*

6

0: 1 hour duration

*90: 1,5 hour duration

18

0: 

3

 hour duration

(*) 

Non-Maintained  operation:  The  luminaire 

lights  its  illumination  source,

 

only  in    power 

supply’s failure. 
Maintained  operation:  The  luminaire  lights  its 
illumination  source,  when  it  is  powered  by  the 
mains power supply or not

Battery replacement. 

It can be done only by a competent person and 
after the mains interruption.

1 .

  F o l l o w   t h e   s t e p   2  

o

f   t h e   i n s t a l l a t i o n  

procedure.

2.

  Disconnect  the 

cables

  and  remove  the  old 

battery.

3.

  Connect  the  new  battery  with  the  same  type 

(step 

3

 of the installation procedure) and place it 

in the position

  

of the old one.

4.

 Follow the step 5 of the installation procedure 

and power the device..

3

4

L

N

1

Minimum distance from lighted objects.

NOTE!! 
After finishing the installation you must power the luminaire at least for 24 hours for battery 
charging to perform the named autonomy. 

923029

0

00_

23

_0

23

TEST

button

Cover

retaining

 

screws

Fig

.

 1

Mounting holes

Charge

indicator

Power

indicator