6
Remove the provided RO membrane from the plastic packaging and install into the RO hous
-
ing on the main system bracket as follows:
I. Open RO Housing:
See
Fig. 4.
Remove BLUE tubing lock clip and remove the tubing
from the cap of the RO housing on the main system bracket.
**
Using the provided
small wrench, remove the RO housing cap by turning counter-clockwise.
II. Install RO Membrane in Housing:
See
Fig. 5.
Insert the double banded end of the RO
membrane into the RO housing first.
III. Close RO Housing:
Hand twist the RO housing cap back onto the RO housing by turn
-
ing clockwise.
Using the provided small wrench, completely tighten the cap onto the
RO housing.
See
Fig. 6.
Re-insert tubing into RO housing cap and re-attach BLUE tub
-
ing lock clip to secure tubing.
Fig. 4
Fig. 5
Fig. 6
**Important!
The tubing connection on the membrane housing cap MUST be removed prior to opening the membrane housing to pre
-
vent the tubing connection elbow from breaking inside the housing cap. Refer to page 5 for Quick Connect Instructions.
RO Membrane Installation
Important!
Step 1: Remove Tubing