![olympia electronics Double Easy Light GR-391/L Quick Start Manual Download Page 2](http://html.mh-extra.com/html/olympia-electronics/double-easy-light-gr-391-l/double-easy-light-gr-391-l_quick-start-manual_3866099002.webp)
Page
2
from
4
923393000_09_008
PLACING
Α-
CRV PARTS
To install the curve crystal
Α-
CRV
you must first install the
included plastic extension to mount it on the TEST button
.
MARKING PANEL SP-114
A marking panel SP-114 can be installed on the
luminaire in 3 different locations. This marking
panel is installed perpendicular to the diffusor of
the luminaire, as shown on the pictures below.
The panel is pre-printed and has a plastic
accessory on each side that is used to fasten the
panel to the luminaires
.
There are 2 arrow stickers that can be placed in
each side of the marking panel to point to the
desired direction.
Placing the SP-114 marking panel
Place the plastic mounting accessories of the
marking panel as shown on pictures
.
ΝΟΤΕ!!
This marking panel (SP type) can not
be installed on CRV luminaires.
362
134
134
90
Test
Double
Easy Light
luminaires
60
134
350
134
Double
Easy Light
luminaires
/CRV
Battery replacement
.
It can be done only by a competent person and after the mains
interruption
.
1.
Turn the luminaire anti-clockwise and detach it from its
mounting base. Use a flat blade screwdriver and remove the
diffusors
.
2.
Unfasten the reflector’s retaining screws.
3. Disconnect the connector and remove the old battery.
4. Connect the new battery with the same type and place it in
the position of the old one.
5.
Replace the removed parts (step 1 and 2) and power the
device
.
2
Plastic base
Diffusor
Diffusor
Reflector
1