240011511 REV. C [05/31/2017]
Table A-6 Direct Drive Blower Motor Setup - 1/2 HP PSC 4 Speed Motor
Furnace
Model
Blower
Heating Blower Set-Up
Cooling Capacity
0.20 in. w.c.
0.50 in. w.c.
Tons
CFM Range
@ 0.5 in. w.c.
Speed
Speed
LRF65
100-10T DD
Low
Low
3
766-1249
LRF80
100-10T DD
Low
Medium Low
3
766-1249
LRF90
100-10T DD
Medium Low
Medium High
3
766-1249
LRF100
100-10T DD
Medium High
High
3
766-1249
Table A-7 Direct Drive Blower Characteristics - 1/2 HP PSC 4 Speed Motor
Furnace
Model
Blower
Motor
FLA
∆T
Speed
CFM
External Static Pressure – Inches w.c.
0.20
0.30
0.40
0.50
0.60
LRF
65 – 100
100-10T DD
6.0
55-85 °F
High
1455
1383
1314
1249
1160
Med-High
1427
1345
1286
1216
1128
Med-Low
1234
1170
1135
1054
973
Low
827
819
805
766
709
APPENDIX A - CHECK OUT AND ADJUSTMENTS
TIP
Formulas will assist with design of duct-work and determination of air flow delivery.
CFM = Bonnet Output / (1.085 x System Temperature Rise (
∆
T
)
System Temperature Rise (
∆
T
) = Bonnet Output / (1.085 x CFM)
Table A-8 Belt Drive Blower Motor Setup - 1/2 HP PSC Single Speed Motor
Furnace
Model
Blower
Heating Blower Set-Up
Cooling Capacity
0.20 in. w.c.
0.2 in. w.c.
Pulley
Belt
Tons
CFM Range
Motor
Blower
LRF65
100-10T
3-1/4" X 1/2" 3 T.O.
6" X 3/4"
4L370
2.5-3.0
960-1300
LRF80
100-10T
3-1/4" X 1/2" 2 T.O.
LRF90
100-10T
3-1/4" X 1/2" 1 T.O.
LRF100
100-10T
3-1/4" X 1/2" 0 T.O.
Table A-9 Belt Direct Drive Blower Characteristics - 1/2 HP PSC Single Speed Motor
Furnace
Model
Motor
FLA
∆T
Blower
Motor
Pulley
Turns Out
CFM
External Static Pressure – Inches w.c.
0.1
0.2
0.3
0.4
0.5
LRF65
7.9
55-85 °F
100-10T
0
1400
1300
1183
1052
904
LRF80
1
1307
1190
1061
915
752
LRF90
2
1217
1076
927
744
544
LRF100
3
1110
960
793
536
248
A.5 Blower Setup