BLOWER REMOVAL
This furnace has a blower sealing system, which is designed to be tight and rattle free. Refer
to the instructions and pictures below.
1) Shut off oil and power to furnace.
2) Remove the two (2) screws securing the blower door
(Figure 1).
3) Open blower compartment (Figure 1).
4) Disconnect the wiring to the blower motor.
5) Remove the screw securing the blower side to
the separating panel (Figure 2).
6) Slide the blower toward you and get the blower
out of the furnace (Figure 3).
Figure 1
Figure 2
Figure 3
Screws
Blower Door