NOTES:
1.
Refer to the condensate management and drain hose
plumbing for different configurations in this document. No
hose clamps are needed for the condensate pan hook up.
2.
Drip leg in the gas line must be installed.
3.
The furnace controls require correct polarity on the power
supply and a proper ground.
4.
Y & G must be connected to the control board for cooling
operation.
5.
Measure the supply air static pressure after the furnace
before the indoor coil. Record this positive number. Measure
the return air static pressure after the filter. Record this neg-
ative number. Treat the negative number as a positive num-
ber, and add it to the recorded supply static pressure
reading. This sum is the total system external static pres-
sure.
6.
Inlet gas pressure for natural gas should be 7” and that for
propane should be 11” w.c. Nominal manifold gas pressure
is 3.5” for natural gas and 10” w.c. for propane at high fire
and 1.6” for Natural gas and 4.0” for Propane on low fire.
7.
If thermoplastic indoor coil drain pans are to be installed in
the up-flow/horizontal configuration, then extra 2” minimum
spacing may be needed to ensure against drain pan distor-
tion.
8.
External filters required on all configurations.
9.
Electrical entry is available on both sides of the casing.
10. All 33”, 95% furnaces are approved for single-pipe and 2-
pipe systems. For single pipe systems it is recommended to
install the combustion air coupling provided and install
approximately 18” of PVC pipe on the furnace.
11. Do not install an external condensate trap on these fur-
naces, as it will prevent the unit from operating correctly.
†
Other airflows are available. see Tech Guide for all CFM options.
LED INDICATOR
Models
Airflow CFM (Bottom Return without Filters)
Gas Pipe
Connection, NPT
Fuse or Circuit
Breaker
0.5" ESP (Nominal)
†
Low
Med-Lo
Med-Hi
High
TM9T060B12MP11
713
872
1082
1243
1/2”
15
TM9T080B12MP11
854
1008
1179
1370
1/2”
15
TM9T080C16MP11
838
1250
1465
1671
1/2”
15
TM9T100C16MP11
819
1224
1477
1706
1/2”
15
TM9T100C20MP11
1183
1430
1712
1934
1/2”
20
TM9T120D20MP11
1190
1430
1739
1977
1/2”
20
Models
Input
Rate
Total Unit
Amps
Air Temp. Rise
Max Input °F
Air Temp. Rise
Min Input °F
Time For 1 ft
3
Natural Gas
(1030 Btu/Ft
3
) Seconds
(On Max. Rate)
Max
Min
TM9T060B12MP11
60,000
39,000
8.9
35 - 65
35 - 65
62
TM9T080B12MP11
80,000
52,000
8.9
45 - 75
20 - 50
46
TM9T080C16MP11
80,000
52,000
10.5
45 - 75
25 - 55
46
TM9T100C16MP11
100,000
65,000
10.5
35 - 65
35 - 65
37
TM9T100C20MP11
100,000
65,000
16
45 - 75
20 - 50
37
TM9T120D20MP11
120,000
72,000
16
45 - 75
35 - 65
31
Indication
Condition
Slow Green Flash
Normal operation.
Slow Amber Flash
Normal operation with call for heat.
Any Red Flash
Fault Condition.
Any Rapid 4 Flashes
Potential fault codes / conditions.
This document does not replace the installation instructions, which must be referred to for
detailed information.
CLEARANCES:
All furnaces approved for alcove and attic installation.
DIMENSIONS:
Cabinet Size
A (in)
B (in)
All 'B' Cabinet Furnaces
17-1/2"
16-3/8"
All 'C' Cabinet Furnaces
21"
19-7/8"
All 'D' Cabinet Furnaces
24-1/2"
23-3/8"
Application
Upflow
Downflow
Horizontal
Top
1" 0" 0"
Vent
0" 0" 0"
Rear
0" 0" 0"
Side
0" 0" 1"
Front
1
1. 24" clearance in front and 18" on side recommended for service access.
0" 0" 0"
Floor
Combustible
Combustible
2
2. For combustible floors only when used with special sub-base.
Combustible
Closet
Yes
Yes
Yes
Line Contact
No
No
Yes
SUPPLY END
RETURN END
LEFT SIDE
Combustion Air Inlet
Condensate Drain
(Downflow)
Vent Connection
Outlet
Thermostat
Wiring
29.5”
28.5”
RIGHT SIDE
Condensate Drain
(Downflow)
14”
1”
1.5”
23”
Combustion Air Inlet
Gas Pipe
Entry
Electrical
Entry
Condensate
Drain
Optional Return Air
Cutout (Either side)
FRONT
A
33”
Clips can be flipped
into the up position
for coil cabinet or
plenum attachment
A-COIL
Follow all national and local codes and standards in addition to this document.
The installation must comply with regulations of the serving gas supplier, local building,
heating, plumbing, and other codes. In absence of local codes, the installation must comply
with national codes and all authorities having jurisdiction.
B
24.25”
.56”
.56”
20”
3”
23.8”
.56”
Combustion
Air Inlet
2” Diameter
Vent Connection
Outlet
B
Vent Connection
Outlet
Subject to change without notice. Printed in U.S.A.
1083297-URG-B-0918
Copyright
©
2018 by Johnson Controls, Inc. All rights reserved.
Supersedes: 1083297-URG-A-0114
York International Corp.
5005 York Drive
Norman, OK 73069
QUICK REFERENCE GUIDE
96% TWO STAGE PSC MULTI-POSITION
RESIDENTIAL GAS FURNACES (33” TALL)