12
Installation of the water connec-
tions
The water pipes can be laid through the floor or rear
panel. When connecting the pipes at the rear, the
pre-stamped holes in the rear panel should be
punched out.
Ventilation valve
The rear panel of the oven must be removed in order
to install the temperature sensor for the water heat
exchanger. Slide the temperature sensor into the
right-hand thermometer pocket and secure it using
the threaded screw.
Olsberg Equipment
Installation unit
•
The return flow booster valve is integrated and
set to 55°C.
•
An internal circulation function is also integrated.
This means the buffer can also be charged via
circulation if the circulation pump is not operating
due to a loss of power, for example.
Temperature Difference Controller
•
The temperature difference controller regulates
the circulation pump independently of the water
temperature. This ensures the circulation pump
only runs when the water temperature in the
oven is higher than in the buffer tank.
•
2 Pt 1000 temperature sensors are included in
delivery.
•
These sensors are positioned in the immersion
sleeves of the oven’s water heat exchanger and
buffer tank.
The assembly and installation of the temperature
difference controller should be completed in accor-
dance with the separate instructions provided with
the device.
TAS inlet TAS exit
Return flow heater Heating inlet
Sensor pocket
for the TAS
Sensor pocket for the
temperature sensor:
Water heat exchanger
à
Return from the
buffer tank
Inlet to the
buffer tank
Outlet from
the oven
Return to
the oven